迅达9300扶梯调试
“迅达9300扶梯调试”相关的资料有哪些?“迅达9300扶梯调试”相关的范文有哪些?怎么写?下面是小编为您精心整理的“迅达9300扶梯调试”相关范文大全或资料大全,欢迎大家分享。
迅达9300调试资料
迅达9300调试资料
Escalator/moving walk
9000
MICONIC F4 J 595 102 C
Version V4003
调试
控制器
页 1/10
Schindler AG, Vienna
KFE/SCT/ASI
目录
1 电源线连接................................................................................................................3 2 首次启动前的检查.....................................................................................................3 3 停止期间的检查.........................................................................................................4 4 启动学习运行........................................................
迅达9300调试资料
迅达9300调试资料
Escalator/moving walk
9000
MICONIC F4 J 595 102 C
Version V4003
调试
控制器
页 1/10
Schindler AG, Vienna
KFE/SCT/ASI
目录
1 电源线连接................................................................................................................3 2 首次启动前的检查.....................................................................................................3 3 停止期间的检查.........................................................................................................4 4 启动学习运行........................................................
迅达扶梯9300AE故障代码
(迅达9300AE 扶梯 故障码)
E10 上端左侧梳齿板触点 E11 上端左侧扶手带入口触点 E12 上端裙板触点 E13 下端控制接触器 E14 下端急停 E15 下端左侧梳齿板触点 E16 下端左侧扶手带入口触点 E17 涨紧链触点 E18 马达超速- E19 驱动链断裂触点 E1A 上端烟雾探测器 E1b 扶手带在位触点 E1c 马达欠速 E1d 上端梯级防跳触点 E1E 下端梳齿板加热 E20 手轮触点 E22 STOP开关1,上端 E24 PTC热敏电阻,上端 E26 运行方向出错 E28 下端梯级水平触点 E
迅达扶梯故障代码
扶梯静止时LED显示 LED3(红灯) 闪
安全回路断开,运行闭锁,
DIL开关不在正常位置(厂家预置位置)
停车闭锁
LED2(黄灯) 闪
亮
扶梯准备好运行
起动过渡阶段
LED1(绿灯) 闪
亮
额定运行
LED1和LED2 交替闪 自动润滑信号
运行状态和出错显示 r 0 测试运行/检修运行 r 0 安全回路开路
r r 复位开关DRES1不在OFF位置 d 0 准备好运行 d 连续运行 A 自动运行
t t TUV速度模拟运行 d 下行 u 上行
- 星形运行/变频运行/主接触器吸合(直接启动) c 夜间停止服务功能有效 L 润滑故障 扶梯故障显示 --
(PHKE)
“偏差值”出错
钥匙开关没复位
00 (JR-U,JR-T) 10***
(KKP-T,KPV-T) 上部梳齿板触点
11 (KHLE-T) 上部扶手带入口触点 12 (KSL) 13 (SKVS) 14 (DH) 15***
围裙板触点
硬件监控HWD继电器出错 急停车
(KKP-B,KKPV-T) 下部梳齿触点
16 (KHLE-B) 下部扶手带入口触点 17 (KKS-B,KUS) 链条涨紧触点 20*
ROM检验出错
安全制动器不在关位置
迅达扶梯故障码
代号故障码
上左梳齿板KKP-TLE10
上左扶手入口KHLE-TLE11
上左裙板KSL-TE12
下控制接触器不吸合SKVBE13
紧急停车DHE14
下左梳齿板KKP-BLE15
下左扶手入口KHLE-BLE16
梯级链延伸触点KKS-BE17
马达超速15%INBMGE18
主驱动链断裂触点KAK-TE19
上烟雾探测器KBFM-TE1A
扶手带松脱触点KHLAE1b
马达速度过慢INBMGE1C
上梯级弹跳触点KUS-TE1d
下梳齿板加热器RTHFK-BE1E
下围裙板触点KSL-BE1F
飞轮触点KHRE20
紧急拉动停制KHRLE21
上制停按键1JH1-TE22
上梳齿板KKPV-TE23
上PTC热敏开关WTHM-TE24
接触器不释放SFEE25
运行方向出错INVKE26
下制停按键1JH1-BE27
下梯级下沉触点KKA-BE28
下梳齿板加热器KKPV-BE29
上停止开关JH-TE2A
扶手带拉长接点KHLLE2b
下停止开关JH-BE2C
变频器故障GFUE2d
停止开关(外控制柜)JH-AE2E
上梯级板触点KDMR-TE2F
PES超速15%INVK-T/BE30
PES欠速INVK-T/BE31
左扶手带速度监控接点INHL-LE32
石扶手带速度监控接点INHL-RE33
迅达 300C MMR调试手册
迅达 300C MMR调试手册
目录
1 安全 3
2 准备工作...................................................................................................4 3 Mic-SE32A-0110控制板...........................................................................5 3-1 Mic-SE32A-0110控制板概貌..............................................................5 3-2 Mic-SE32A-0110控制板端口说明.......................................................5 4 SM-02-C轿厢板和SM-03-B指令板..........................................................9 4-1 SM-02-C轿厢板和SM-03-B指令板概貌....................
迅达 300C MMR调试手册
迅达 300C MMR调试手册
目录
1 安全 3
2 准备工作...................................................................................................4 3 Mic-SE32A-0110控制板...........................................................................5 3-1 Mic-SE32A-0110控制板概貌..............................................................5 3-2 Mic-SE32A-0110控制板端口说明.......................................................5 4 SM-02-C轿厢板和SM-03-B指令板..........................................................9 4-1 SM-02-C轿厢板和SM-03-B指令板概貌....................
迅达电梯3300故障代码
8 附录 B:故障代码 图例:
C1,C2,C3, --故障原因1,2,3 A1,A2,A3, --解决行动1,2,3
0001 电梯致命故障 电梯持续死机,无法操作。注意,该故障代码经常跟随其他故障代码一起出现。 C1,多种原因 A1,通过检查电梯故障表,找到先前的故障信息,以确定故障的关键原因。
0002 安全回路 安全回路意外断开或没有按程序闭合。 C1,安全回路意外断开(例如,当电梯在运行中) A1,检查安全回路断开处的接触点。检查SMIC上110V的保险丝。 C2,安全回路没有按预计闭合。当所有厅轿门关闭后,安全回路应该随之闭合。 A2,检查门触点的安全回路。检查参数(CF03 PA13)门关闭与安全回路闭合 之间的延时时间。
0003 超载 C1:轿厢超载 A1:轿厢减磅 C2:称重装置错误信号 A2:检查称重装置和相关接线。如果有信号但测量不准,重做称重校准。
0005 没有电源
0008 保留/独立状态
0012 无授权 因没有SIM卡或使用非法的SIM卡,电梯停止运行。 C1:没有迅达公司的SIM卡,或使用了其他电梯的SIM卡 A1:检查SIM卡是
迅达电梯3300故障代码
8 附录 B:故障代码 图例:
C1,C2,C3, --故障原因1,2,3 A1,A2,A3, --解决行动1,2,3
0001 电梯致命故障 电梯持续死机,无法操作。注意,该故障代码经常跟随其他故障代码一起出现。 C1,多种原因 A1,通过检查电梯故障表,找到先前的故障信息,以确定故障的关键原因。
0002 安全回路 安全回路意外断开或没有按程序闭合。 C1,安全回路意外断开(例如,当电梯在运行中) A1,检查安全回路断开处的接触点。检查SMIC上110V的保险丝。 C2,安全回路没有按预计闭合。当所有厅轿门关闭后,安全回路应该随之闭合。 A2,检查门触点的安全回路。检查参数(CF03 PA13)门关闭与安全回路闭合 之间的延时时间。
0003 超载 C1:轿厢超载 A1:轿厢减磅 C2:称重装置错误信号 A2:检查称重装置和相关接线。如果有信号但测量不准,重做称重校准。
0005 没有电源
0008 保留/独立状态
0012 无授权 因没有SIM卡或使用非法的SIM卡,电梯停止运行。 C1:没有迅达公司的SIM卡,或使用了其他电梯的SIM卡 A1:检查SIM卡是
迅达电梯3300故障代码
8 附录 B:故障代码 图例:
C1,C2,C3, --故障原因1,2,3 A1,A2,A3, --解决行动1,2,3
0001 电梯致命故障 电梯持续死机,无法操作。注意,该故障代码经常跟随其他故障代码一起出现。 C1,多种原因 A1,通过检查电梯故障表,找到先前的故障信息,以确定故障的关键原因。
0002 安全回路 安全回路意外断开或没有按程序闭合。 C1,安全回路意外断开(例如,当电梯在运行中) A1,检查安全回路断开处的接触点。检查SMIC上110V的保险丝。 C2,安全回路没有按预计闭合。当所有厅轿门关闭后,安全回路应该随之闭合。 A2,检查门触点的安全回路。检查参数(CF03 PA13)门关闭与安全回路闭合 之间的延时时间。
0003 超载 C1:轿厢超载 A1:轿厢减磅 C2:称重装置错误信号 A2:检查称重装置和相关接线。如果有信号但测量不准,重做称重校准。
0005 没有电源
0008 保留/独立状态
0012 无授权 因没有SIM卡或使用非法的SIM卡,电梯停止运行。 C1:没有迅达公司的SIM卡,或使用了其他电梯的SIM卡 A1:检查SIM卡是