欧瑞E1000变频说明书
更新时间:2023-04-24 03:28:01 阅读量: 实用文档 文档下载
E1000变频说明书
目 录
一、产品简介··········································································································1 1.1 产品铭牌······························································································1 1.2 产品外观······························································································1 1.3 产品命名规则·······················································································2 1.4 技术规范······························································································2 1.5 产品设计执行标准···············································································4 1.6 安全事项······························································································4 1.7 注意事项······························································································5 1.8 日常检查和保养···················································································5 二、 控制面板········································································································7 2.1 2.2 2.3 2.4 2.5
面板说明·····························································································7 面板操作·····························································································8 参数设置·····························································································8 功能码区内与区间的切换·································································9 面板显示内容···················································································10
三、 安装接线······································································································11 3.1 3.2 3.3 3.4 3.5 3.6
变频器安装·······················································································11 接线··································································································11 控制端子功能简介···········································································12 功率回路推荐配线···········································································16 保护导体(地线)的截面积····························································16 总体接线示意图···············································································17
四、操作及简单运行····························································································19 五、功能参数········································································································26
E1000变频说明书
5.1 基本参数·······························································································26 5.2 运行控制·······························································································34 5.3 多功能输入输出端子············································································41 5.4 模拟量输入输出····················································································45 5.5 多段速度控制························································································49 5.6 辅助功能·······························································································53 5.7 故障与保护····························································································55 5.8 电机参数区····························································································57 5.9 通讯参数·······························································································57 5.10 PI参数区··························································································58 附录1 常见故障处理···························································································59 附录2 产品一览表及结构型式一览表······························································61 附表3 制动电阻选型表·······················································································63 附录5 功能码速查表·························································································74 敬告用户:···············································································································89
E1000变频说明书
产 品 简 介
一、产品简介
本使用手册简要介绍了E1000系列变频器的安装接线、参数设定及操作使用的有关事项,务请妥善保管。如果使用中发生故障,请与厂家或经销商联系。
1.1 产品铭牌
以E1000系列单相交流220V输入,0.75KW变频器为例,其铭牌如图所示。
1PH表示单相输入;220V、50/60Hz表示输入电压和额定频率。
3PH表示输出三相,4.5A、0.75KW表示额定输出电流和功率。
0.00~650.0Hz表示输出频率范围。
图1-1 产品铭牌
1.2 产品外观
积小巧,造型美观且强度高、韧性好。
E1000系列变频器外观结构为塑壳,采用壁挂式安装结构。塑料外壳采用优质材料模压而成,体
以E1000-0007S2为例,产品外形及结构部件如图1-2所示。
图1-2 产品外形及结构部件
控制盒 通风栅 控制端子 功率端子 安装孔 散热器
E1000变频说明书
产 品 简 介
1.3 产品命名规则
E1000 - 0007 S2 F1 K B P R
注:在订货时,请填写完整的整机型号,否则将有可能发错货,影响您的正常使用。
1.4 技术规范
表1-1 E1000系列变频器技术规范
E1000变频说明书
产 品 简 介
输入 输出
项 目
额定电压范围
额定频率
额定电压范围
频率范围 载波频率 输入频率分辨率
控制方式 过载能力 转矩提升 V/F曲线 直流制动
点动控制 自动循环、多段速运行
内置PI 频率设定 起/停控制
内 容
三相380V±15%;单相220V±15% 50/60Hz
三相0~380V;三相0~220V 0.00~650.0Hz
3000~15000Hz;固定载波和随机载波可选择(F159) 数字设定:0.01Hz,模拟设定:上限频率×0.1% VVVF控制
150%额定电流60秒
手动转矩提升0.1%~30.0%(VVVF)
三种方式:直线型、平方型、自定义V/F曲线
直流制动频率:1.0~5.0 Hz,制动时间:0.0~10.0秒 点动频率范围:下限频率~上限频率;点动加减速时间:0.1~3000.0秒
通过自动循环或控制端子实现最多15段速运行 可方便实现过程闭环控制系统
电位器或外部模拟信号(0~5V,0~10V,0~20mA);控制面板(端子)▲/▼键、外部控制逻辑及自循环设定 端子控制、控制面板控制、通讯控制
三种通道:控制面板给定、控制端子给定、串行通讯口给定
主频率源:数字给定、模拟电压给定、模拟电流给定、串行口给定等
5种辅助频率。可灵活实现辅助频率微调、频率合成等
控制方式
操作功能
运行命令通道 主频率源 辅助频率源
选配件 保护功能 显 示
内置EMI滤波器、内置制动单元、MODBUS通讯、带电位器本地控制面板、远控面板输入缺相,输出缺相,输入欠电压,直流过电压,过电流,过载,电流失速,过热,外部干扰等
LED数码管显示当前输出频率、当前转速(rpm)、当前输出电流、当前输出电压、当前线速度、故障类型以及系统参数、操作参数;LED灯指示变频器当前的工作状态
设备场所
室内,不受阳光直晒,无尘埃、腐蚀性气体、可燃性气体、油雾、水蒸汽、滴水或盐份等 -10℃~+50℃
90%以下(无水珠凝结现象) 0.5g(加速度)以下
1000米以下(海拔超过1000米需降额使用)
环境条件
环境温度 环境湿度 振动强度 海拔高度
适配电机 0.2~7.5KW
E1000变频说明书
操 作 面 板
1.5 产品设计执行标准
z
IEC/EN 61800-5-1:2003 可调速电气传动系统安全要求——电气、热及能量;
IEC/EN 61800-3: 2004 可调速电气传动系统;第三部分:产品的电磁兼容性标准及其特定的试验方法
z
1.6 安全事项
● 安装前,请认真确认变频器铭牌的型号、额定值。检查本机是否有运输破损现象,如变频器受损
或缺件请勿使用,以免有安全隐患。
● 安装使用环境无雨淋、水滴、蒸汽、粉尘及油性灰尘;无腐蚀、易燃性气体、液体;无金属微粒
或金属粉末等。环境温度在-10℃~+50℃范围内。
● 请安装在金属等阻燃物质上,远离可燃物。 ● 请勿将导线头或螺钉等异物掉入变频器内。
● 变频器的可靠性很大程度取决于温度,周围温度升高10℃,变频器寿命减半。由于变频器的错误
安装或不合适固定,将使变频器产生温升或使周围温度升高,这可能导致故障或损坏等意外事故。
● 变频器装在控制柜内,应保证控制柜与外界通风流畅。请垂直安装变频器,便于热量向上散发,
不能倒置;若柜内有较多变频器时,为保证变频器的散热空间最好将变频器并排安装;在需要上下安装时,请安装隔热导流板(详见图1-3)。
安装在控制柜内
通风扇的位置
(正确)(不正确)
变频器变频器
变频器
变频器
内置冷却风扇
( 正确例)
(错误例)
E1000变频说明书
操 作 面 板
垂直安装
图1-3 变频器安装示意图
1.7 注意事项 1.7.1使用须知
z 断电后15分钟内,请勿触摸内部器件。待完全放电后,方才安全。
z 功率端子L1/R、L2/S、L3/T接市电380V(市电220V接L1/R、L2/S端子上),输出端子U、V、W接电机。
z 接地应可靠,接地电阻不得超过4Ω;电机与变频器分别接地,切不可串联接地。 z 变频器运行中请勿在输出端切换负载。
z 控制回路配线应与功率回路配线相互分开,以避免可能引起的干扰。 z 信号线不宜过长,否则会增加共模干扰。
z 符合表1-1 E1000系列变频器技术规范”对周围环境要求。
1.7.2特别警告
● 切勿碰触变频器内功率端子,以防导致电击。
● 变频器通电前,必须确认变频器输入电源电压等级正确。 ● 不要将输入电源连接到U、V、W或PE端子上。
● 不要将变频器安装在阳光照射的地方,不要堵塞变频器的散热孔。 ● 变频器加电前要重新装好所有保护盖,以防电击。 ● 只允许专业人员进行维护,检查或更换零部件。
1.8 日常检查和保养 1.8.1定期检查
● 定期清洁冷却风扇和风道,并检查是否正常;定期清洁机内积存的灰尘。 ● 定期检查变频器的输入输出接线,接线端子是否有拉弧痕迹,检查电线是否老化。 ● 检查各端子接线螺钉是否紧固。
● 严禁带电作业。
E1000变频说明书
操 作 面 板
● 检查变频器是否受到腐蚀。
1.8.2易损件更换
变频器易损件主要有冷却风扇和滤波电解电容。
● 风扇使用寿命一般为2~3年,用户可以根据运行时间确定更换变频器的冷却风扇。冷却风
扇可能损坏原因:轴承磨损、叶片老化。检查风扇叶片等是否有裂缝,开机时声音是否有异常振动声,以此来判断是否需要更换。
● 滤波电解电容使用寿命一般为4~5年,用户可以根据运行时间确定更换变频器的滤波电解
电容。滤波电解电容可能损坏原因:输入电源品质差,环境温度高,频繁的负载跳变,电解质老化。通过有无液体漏出、安全阀是否已凸出,静电电容的测定,绝缘电阻的测定来判断是否需要更换。
1.8.3存储
● 存储时尽量按原样装在本公司的包装箱内。
● 为防止长时间存放导致电解电容的劣化,保证在半年内充一次电,通电时间至少5小时。
1.8.4日常保养
由于环境的温度、湿度、粉尘及振动的影响,会导致变频器内部的器件老化、潜在的故障发生并降低了变频器的使用寿命。因此对变频器的日常保养非常必要。
日常检查:
● 电机运行中,声音是否有异常变化。 ● 电机运行中,是否产生振动。 ● 变频器的安装环境是否发生变化。
● 变频器风扇运行是否正常,变频器是否过热。
日常清洁:
应使变频器始终保持在清洁状态;应及时清除变频器表面灰尘,防止积尘、金属粉尘、油污、
水等进入变频器内部。
E1000变频说明书
操 作 面 板
二、 控制面板
E1000系列变频器有两种形式(带电位器和不带电位器)的控制面板,按键功能和指示灯作用详见面板说明。
2.1 面板说明
面板分为三部分,即数据显示区、状态指示区和控制面板操作区,如图2-1所示。
图2-1 两种形式的控制面板
E1000变频说明书
操 作 面 板
2.2 面板操作
面板上的所有按键均对用户开放。其功能作用见表2-1。 表2-1 按 键 说 明
2.3 参数设置
变频器内有众多的功能参数,用户更改这些参数可以实现不同的控制运行方式。需要说明的是,若用户设置密码有效(F107设置为1),在断过电或发生过保护之后,如果要设置参数,必须先输入用户密码,即按表2-2方式调出F100,输入正确的密码。出厂时,用户密码为无效的,即用户不需要设置密码即可设置相应的参数。
表2-2 参数设置步骤
上述操作是在变频器处于停机状态下完成的!
E1000变频说明书
操 作 面 板
2.4 功能码区内与区间的切换
本产品对用户开放的参数(功能码)共有300多个,分为十个区,如表2-3所示。 表2-3 功能码分区
区间名称 基本参数区 运行控制区 多功能输入输出端模拟量输入输出区 多段速度区
功能码分段F100~F160 F200~F230 F300~F330 F400~F440 F500~F580
区间号 1 2 3 4 5
区间名称 辅助功能区 定时控制及保护区 电机参数区 通讯功能区 PI参数控制区
功能码分段F600~F630 F700~F740 F800~F830 F900~F930 FA00~FA30
区间号6 7 8 9 10
由于功能码多,参数设置耗费时间,为此专门设计了“在功能码区内和功能码区之间切换”的功能,使参数设置方便易行。
按“方式”键,使控制面板显示功能码,此时若按“▲”或“▼”键,则功能码在区内循环的递增或递减;如果再按一次“停/复”键,操作“▲”或“▼”键时,则功能码在功能码区之间循环变化。
例如当前显示功能码为F111,DGT指示灯点亮,按“▲”/“▼”键时,功能码在F100~F160内循环地递增或递减;再次按“停/复”键,DGT指示灯熄灭,操作“▲”/“▼”键时,则功能码在9个区之间循环变化,如F211、F311…FA11、F111…,如图2-2所示。
(说明书中用相应目标频率值)
示闪烁显示
正确输入用户密码
(当前显示为DGT 熄灭DGT 点亮
图2-2 功能码区内和区间切换
E1000变频说明书
操 作 面 板
2.5 面板显示内容
面板显示项目内容及说明
E1000变频说明书
安 装 接 线
三、 安装接线 3.1
变频器安装
变频器应垂直安装,如图3-1所示。其周围应保证有效的通风空间
下表给出了变频器安装的间隙尺寸(推荐值)
。
变频器类型 壁挂式
A≥150mm
间 隙 尺 寸
B≥50mm
图3-1 变频器安装示意图
3.2
z
接线
输入三相时L1/R、L2/S、L3/T(单相时L1/R、L2/S)接电网电源,PE接大地,U、V、W接电机。 z z
注意电机也必须接地,否则容易产生干扰、电机带电。
对于E1000型变频器,如果负载惯性不太大,可以只配制动电阻即可。
单相220V 0.2KW~0.75KW功率端子示意图
E1000变频说明书
安 装 接 线
单相220V 1.5KW~2.2KW及三相380V 0.75KW~7.5KW功率端子示意图
(此图仅为示意图,实际产品的功率端子可能与上图未完全一致,接线时务必注意!)
功率回路端子说明
端子名称 电源输入端子 变频器输出端子
接地端子 制动端子
端子标号 L1/R、L2/S、L3/T
U、V、W PE P、B
端子功能说明
三相380V交流电压输入端子,单相220V接L1/R、L2/S。变频器功率输出端子,接电动机。 变频器接地端子。 外接制动电阻。
控制回路接线如下:
A) 单极性(NPN型信号)输入控制端子如下图所示:
TA TB TC DO124VCMOP1OP2OP3OP4OP5OP6 10VAI1B) 双极性(兼容NPN型和PNP型信号)输入控制端子如下图所示: 3.3
TA TB TC DO124VGPCMOP1OP2OP3OP410VAI1AI2控制端子功能简介
操作使用变频器的关键在于正确灵活地使用控制端子。当然,控制端子并不是独立使用,而要
配合相应的参数设置。此处介绍控制端子的基本功能作用,用户可结合后文的相关内容“端子定义功能”,加以灵活使用。
E1000变频说明书
安 装 接 线
表3-1 控制端子功能简介 端 子 DO1 TA TB TC AO1 AO2 10V AI1
输入
信号
AI2
模拟 电源 输出 信号
继电器触点
TC为公共点,TB-TC为常闭触点,TA-TC为常开触点;触点电流不超过2A,电压不超过250VAC。
类 别
名 称 功 能 说 明 表征功能有效时该端子与CM间为0V,停机时其值为24V。
端子1
输出端子功能按出厂值定义;也可通过修改功能码,改变其初始状态。
运行频率 电流显示 自给电源
外接频率表或转速表,其负极接GND。详细介绍可参看F423~F426。外接电流表,其负极接GND。详细介绍可参看F427~F430。 变频器内部10V自给电源,供本机使用;外用时只能做电压控制信号的电源,电流限制在20mA以下。
电压模拟量模拟量调速时,电压信号由该端子输入。电压输入的范围为0~10V,输入端口 地接GND。采用电位器调速时,该端子接中间抽头,地接GND。 模拟量调速时,电压或电流信号由该端子输入。电压输入的范围为电压/电流模0~5V或0~10V,电流输入范围为0~20mA,其地为GND。如果输入拟量输入端为4~20mA,可通过调整相关功能码实现。电压和电流信号的选择可口 通过拨码开关来实现,具体操作方法见表4-2,出厂值该通道默认为
0~20mA电流通道。
外部控制信号(电压控制信号或电流源控制信号)接地端,亦为本机10V电源地。
24±1.5V电源,地为CM;外用时电流限制在50mA以下。 用于选择源极连接方式或漏极连接方式,当GP与24V短接时,数字输入端子为源极连接方式,即低电平信号有效;当GP与CM短接时,数字输入端子为漏极连接方式,即高电平有效。
该端子为有效状态时,变频器点动运行。停机状态和运行状态下,端子点动功能均有效。 该端子为有效状态时,变频器显示“ESP”。 该端子为有效状态时,变频器正向运转。 该端子为有效信号时,变频器反向运转。 故障状态下给于一有效信号,使变频器复位。 运行中给此端子一有效信号,可使变频器自由停机。24V电源及其它控制信号的地。
此端子出厂
时默认与CM短接,为漏极连接方式。
GND 24V
模拟地自给电源地电 源 控制电源
GP
注1
多功能端子
OP1 OP2 OP3 OP4 OP5 OP6
注2
点动端子
数字输入控制端子
外部急停 正转端子 反转端子 复位端子 自由停机
公用端控制电源地
此处输入端子功能按出厂值定义;也可通过修改功能码,将其定义为其他功能。
CM
注1:GP端子只有在双极性输入端子中才有此端子。 注2:在双极性输入控制端子中此端子不存在。
E1000变频说明书
安 装 接 线
数字输入端子接线方法
一般需要用屏蔽电缆,而且配线距离要尽量短,当选用有源信号驱动时,需要对电源的串扰采
取必要的滤波措施。建议采用触点控制方式。
单极性输入控制端子只能实现共源极接线方式;双极性输入控制端子若实现共源极连接方式,需要将GP端子与24V端子用短路片短接,具体接线方式如1、2:
1、 无源共源极接线方式
2、 有源共源极接线方式
E1000变频说明书
安 装 接 线
双极性输入控制端子若实现共漏极连接方式,需要将GP端子与CM端子用短路片短接,单极性输入端子不能实现此种连接方式,具体接线方式如3、4:
3、 无源共漏极接线方式
4、 有源共漏极接线方式
共源极连接方式是目前最为常用的一种方式,双极性输入控制端子出厂值默认为共漏极连接方式,因此用户根据需求进行相应的选择。
E1000变频说明书
安 装 接 线
3.4
功率回路推荐配线
变频器型号 E1000-0002S2 E1000-0004S2 E1000-0007S2 E1000-0015S2 E1000-0022S2 E1000-0007T3 E1000-0015T3 E1000-0022T3 E1000-0037T3 E1000-0040T3 E1000-0055T3 E1000-0075T3
导线截面积(mm)
1.0 1.5 2.5 2.5 4.0 1.5 2.5 2.5 2.5 2.5 4.0 4.0
2
3.5
保护导体(地线)的截面积
U、V、W相的截面积S(mm)
S≤16 16<S≤35 35<S
2
PE的最小截面积S(mm)
S 16 S/2
2
E1000变频说明书
安 装 接 线
3.6 总体接线示意图
下图为E1000系列变频器单相和三相接线示意图。图中指出了各类端子的接线方法,实际使用中并不是每个端子都要接线。 3.6.1 单相变频器接线示意图
单相变频器标准配线图
正在阅读:
欧瑞E1000变频说明书04-24
大班区域观察记录01-10
灾害天气预警应急预案09-11
Linux基本命令(带参考答案)03-05
学生自我评价范文03-16
物联网技术及其应用 - 图文11-04
学心理健康教育论文评选获奖名单通知复习03-08
毕业答辩工程造价有关问题答案09-11
高血压患者随访服务记录表填写注意样板04-30
幼儿园全年工作计划03-28
- 教学能力大赛决赛获奖-教学实施报告-(完整图文版)
- 互联网+数据中心行业分析报告
- 2017上海杨浦区高三一模数学试题及答案
- 招商部差旅接待管理制度(4-25)
- 学生游玩安全注意事项
- 学生信息管理系统(文档模板供参考)
- 叉车门架有限元分析及系统设计
- 2014帮助残疾人志愿者服务情况记录
- 叶绿体中色素的提取和分离实验
- 中国食物成分表2020年最新权威完整改进版
- 推动国土资源领域生态文明建设
- 给水管道冲洗和消毒记录
- 计算机软件专业自我评价
- 高中数学必修1-5知识点归纳
- 2018-2022年中国第五代移动通信技术(5G)产业深度分析及发展前景研究报告发展趋势(目录)
- 生产车间巡查制度
- 2018版中国光热发电行业深度研究报告目录
- (通用)2019年中考数学总复习 第一章 第四节 数的开方与二次根式课件
- 2017_2018学年高中语文第二单元第4课说数课件粤教版
- 上市新药Lumateperone(卢美哌隆)合成检索总结报告
- 变频
- 说明书
- E1000
- 浅谈营造安全文明的施工现场
- 八年级【上】语文活页第二单元答案语文活页第五单元答案
- 第一章:学习心理的基本理论
- 农科大学物理可视化教学探索
- 深圳15-16年一手楼数据明细整理
- 蝴蝶泉边高二精选作文
- 加油站安全生产会议记录
- 小学三年级美术下册教学计划江西版2015
- 高考历史二轮专题复习教案
- 国家电网公司输变电工程通用设计110(66)kV输电线路分册(2011年版
- 江西师范大学文件校发〔2011〕118号关于开展2011年'教学月&#
- 应征公民政治考核表
- 骨干教师培养工作总结
- 食药检测保留国家队?拥抱第三方?
- ABAQUS常问CAE操作集锦
- 基于AVR单片机的自动准同期装置频率测量方法
- 第一章 三维参数化设计概述及
- HRP信息系统在医院设备资产管理中的研究与应用-论文
- 上海大学管理岗位职级制实施细则
- 无机非金属材料工程