Dell Storage Center

SCv2000 and SCv2020 Storage System Deployment Guide

Notes, Cautions, and Warnings

NOTE: A NOTE indicates important information that helps you make better use of your computer.

CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.

WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

Copyright ? 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell? and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.

2015 - 07

Rev. A01

Contents

About this Guide (7)

Revision History (7)

Audience (7)

Contacting Dell (7)

Related Publications (7)

1 About the SCv2000/SCv2020 Storage System (9)

Storage Center Hardware Components (9)

SCv2000/SCv2020 Storage System (9)

Switches (9)

Expansion Enclosures (10)

Storage Center Architecture Options (10)

Storage Center Replication (10)

Storage Center Communication (11)

Front-End Connectivity (11)

Back-End Connectivity (14)

System Administration (15)

SCv2000/SCv2020 Storage System Hardware (15)

SCv2000/SCv2020 Storage System Front-Panel Features and Indicators (15)

SCv2000/SCv2020 Back-Panel Features and Indicators (16)

SCv2000/SCv2020 Storage Controller Features and Indicators (17)

SCv2000/SCv2020 Drives (23)

SCv2000/SCv2020 Storage System Drive Numbering (23)

SC100/SC120 Expansion Enclosure Overview (24)

SC100/SC120 Expansion Enclosure Front-Panel Features and Indicators (24)

SC100/SC120 Expansion Enclosure Back-Panel Features and Indicators (25)

SC100/SC120 Expansion Enclosure EMM Features and Indicators (26)

SC100/SC120 Expansion Enclosure Drives (27)

SC100/SC120 Expansion Enclosure Drive Numbering (27)

2 Install the Storage Center Hardware (28)

Unpack and Inventory the Storage Center Equipment (28)

Prepare the Installation Environment (28)

Safety Precautions (28)

Installation Safety Precautions (29)

Electrical Safety Precautions (29)

Electrostatic Discharge Precautions (30)

General Safety Precautions (30)

Install the Storage System in a Rack (30)

3

3 Connect the Front End (34)

Types of Redundancy for Front-End Connections (34)

Port Redundancy (34)

Storage Controller Redundancy (35)

Multipath IO (35)

Cabling SAN-Attached Host Servers (36)

Connecting to Fibre Channel Host Servers (36)

Connecting to iSCSI Host Servers (48)

Cabling Direct-Attached Host Servers (57)

Preparing Host Servers (57)

SAS Virtual Port Mode (58)

Two Servers Connected to Dual 12 Gb 4-Port SAS Storage Controllers (58)

Four Servers Connected to Dual 12 Gb 4-Port SAS Storage Controllers (59)

Two Servers Connected to a Single 12 Gb 4-Port SAS Storage Controller (61)

Labeling the Front-End Cables (62)

Cabling the Ethernet Management Port (63)

Labeling the Ethernet Management Cables (63)

Cabling the Embedded Ports for iSCSI Replication (64)

Cabling the Replication Port for iSCSI Replication (64)

Cabling the Management Port and Replication Port for iSCSI Replication (65)

Cabling the Embedded Ports for iSCSI Host Connectivity (66)

Two iSCSI Networks using the Embedded Ethernet Ports on a Storage System with Dual

Fibre Channel Storage Controllers (66)

Two iSCSI Networks Using the Embedded Ethernet Ports on a Storage System with Dual

iSCSI Storage Controllers (68)

4 Back-End Cabling and Connecting Power (70)

Expansion Enclosure Cabling Guidelines (70)

SAS Redundancy (70)

SAS Port Types (70)

Back-End Connections for an SCv2000/SCv2020 without Expansion Enclosures (71)

Back-End Connections for an SCv2000/SCv2020 with Expansion Enclosures (71)

SCv2000/SCv2020 and One SC100/SC120 Expansion Enclosure (72)

SCv2000/SCv2020 and Two or More SC100/SC120 Expansion Enclosures (73)

Label the Back-End Cables (74)

Connect Power Cables and Turn On the Storage System (75)

5 Discover and Configure the Storage Center (77)

Locating Your Service Tag (77)

Worksheet to Record System Information (78)

Storage Center Information (78)

4

iSCSI Fault Domain Information (78)

Additional Storage Center Information (79)

Fibre Channel Zoning Information (79)

Supported Operating Systems for Storage Center Automated Setup (80)

Install and Use the Dell Storage Client (80)

Discover and Select an Uninitialized Storage Center (81)

Set System Information (81)

Set Administrator Information (82)

Configure iSCSI Fault Domains (82)

Confirm the Storage Center Configuration (82)

Initialize the Storage Center (83)

Review Fibre Channel Front-End Configuration (83)

Review SAS Front-End Configuration (83)

Configure Time Settings (84)

Configure SMTP Server Settings (84)

Configure Key Management Server Settings (84)

Review the SupportAssist Data Collection and Storage Agreement (84)

Advantages and Benefits of Dell SupportAssist (85)

Provide Contact Information (85)

Update Storage Center (85)

Complete Configuration and Perform Next Steps (86)

Set Up a localhost or VMware Host (86)

Set Up a localhost from Initial Setup (86)

Set Up a VMware vSphere Host from Initial Setup (87)

Set Up a VMware vCenter Host from Initial Setup (87)

Configure Embedded iSCSI Ports (88)

6 Perform Post-Setup Tasks (89)

Verify Connectivity and Failover (89)

Create Test Volumes (89)

Test Basic Connectivity (89)

Test Storage Controller Failover (90)

Test MPIO (90)

Clean up Test Volumes (90)

Send Diagnostic Data Using Dell SupportAssist (91)

Label SC100/SC120 Expansion Enclosures (91)

A Adding or Removing an Expansion Enclosure (93)

Adding Multiple Expansion Enclosures to a Storage System Deployed without Expansion

Enclosures (93)

Cable the Expansion Enclosures Together (94)

Check the Current Disk Count before Adding Expansion Enclosures (94)

Add the SC100/SC120 Expansion Enclosures to the A-Side of the Chain (94)

5

Add the SC100/SC120 Expansion Enclosures to the B-Side of the Chain (95)

Label the Back-End Cables (97)

Adding a Single Expansion Enclosure to a Chain Currently in Service (98)

Check the Disk Count before Adding an Expansion Enclosure (99)

Add an SC100/SC120 Expansion Enclosure to the A-Side of the Chain (99)

Add an SC100/SC120 Expansion Enclosure to the B-Side of the Chain (100)

Label the Back-End Cables (102)

Removing an Expansion Enclosure from a Chain Currently in Service (103)

Release the Disks in the Expansion Enclosure (103)

Disconnect the SC100/SC120 Expansion Enclosure from the A-Side of the Chain (104)

Disconnect the SC100/SC120 Expansion Enclosure from the B-Side of the Chain (105)

B Troubleshooting Storage Center Deployment (109)

Troubleshooting Storage Controllers (109)

Troubleshooting Hard Drives (109)

Troubleshooting Expansion Enclosures (110)

6

About this Guide

This guide describes the features and technical specifications of the SCv2000/SCv2020 storage system. Revision History

Document Number: 8X7FK

Audience

The information provided in this guide is intended for storage or network administrators and deployment personnel.

Contacting Dell

Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area.

To contact Dell for sales, technical support, or customer service issues, go to 9ec4dc87e45c3b3566ec8b7d/support.

?For customized support, enter your system Service Tag on the support page and click Submit.

?For general support, browse the product list on the support page and select your product. Related Publications

The following documentation is available for the SCv2000/SCv2020 storage system.

?Dell Storage Center SCv2000 and SCv2020 Storage System Getting Started Guide Provides information about an SCv2000/SCv2020 storage system, such as installation instructions and technical specifications.

?Dell Storage Center SCv2000 and SCv2020 Storage System Owner’s Manual

Provides information about an SCv2000/SCv2020 storage system, such as hardware features,

replacing customer replaceable components, and technical specifications.

?Dell Storage Center Update Utility Administrator’s Guide

Describes how to use the Storage Center Update Utility to install Storage Center software on an SCv2000 series storage system. Updating Storage Center software using the Storage Center Update Utility is intended for use only by sites that cannot update Storage Center using standard methods.?Dell Storage Center Release Notes

7

Contains information about new features and known and resolved issues for the Storage Center software.

?Dell Storage Client Administrator’s Guide

Provides information about the Dell Storage Client and how it can be used to manage a Storage Center.

?Dell Storage Center Software Update Guide

Describes how to update Storage Center software from an earlier version to the current version.?Dell Storage Center Command Utility Reference Guide

Provides instructions for using the Storage Center Command Utility. The Command Utility provides a command-line interface (CLI) to enable management of Storage Center functionality on Windows, Linux, Solaris, and AIX platforms.

?Dell Storage Center Command Set for Windows PowerShell

Provides instructions for getting started with Windows PowerShell cmdlets and scripting objects that interact with the Storage Center using the PowerShell interactive shell, scripts, and PowerShell hosting applications. Help for individual cmdlets is available online.

?Dell TechCenter

Provides technical white papers, best practice guides, and frequently asked questions about Dell Storage products. Go to 9ec4dc87e45c3b3566ec8b7d/techcenter/storage/.

8

1 About the SCv2000/SCv2020 Storage System

The SCv2000/SCv2020 storage system provides the central processing capabilities for the Storage Center Operating System (OS) and management of RAID storage.

The SCv2000/SCv2020 storage system holds the physical disks that provide storage for the Storage Center. If additional storage is needed, the SCv2000/SCv2020 also supports SC100/SC120 expansion enclosures.

Storage Center Hardware Components

The Storage Center described in this document consists of an SCv2000 or SCv2020 storage system, enterprise-class switches, and expansion enclosures.

To allow for storage expansion, the SCv2000/SCv2020 storage system supports multiple SC100/SC120 expansion enclosures..

NOTE: The cabling between the storage system, switches, and host servers is referred to as front‐end connectivity. The cabling between the storage system and expansion enclosures is referred to as back-end connectivity.

SCv2000/SCv2020 Storage System

The SCv2000 and SCv2020 are 2U storage systems with built-in storage. The SCv2000 is a 2U storage system that supports up to 12 internal 3.5–inch hot-swappable SAS hard drives installed in a four-column, three-row configuration. The SCv2020 is a 2U storage system that supports up to 24 internal 2.5–inch hot-swappable SAS hard drives installed vertically side-by-side.

The SCv2000/SCv2020 storage system contains two redundant power supply/cooling fan modules and up to two storage controllers with multiple IO ports that provide communication with servers and expansion enclosures.

Switches

Dell offers enterprise-class switches as part of the total Storage Center solution.

The SCv2000/SCv2020 supports Fibre Channel (FC) and Ethernet switches, which provide robust connectivity to servers and allow for the use of redundant transport paths. Fibre Channel (FC) or Ethernet switches can provide connectivity to a remote Storage Center to allow for replication of data. In addition, Ethernet switches provide connectivity to a management network to allow configuration, administration, and management of the Storage Center.

About the SCv2000/SCv2020 Storage System9

Expansion Enclosures

Expansion enclosures allow the data storage capabilities of the SCv2000/SCv2020 storage system to be expanded beyond the 12 or 24 internal disks in the storage system chassis.

The SCv2000/SCv2020 storage system supports a total of 168 disks per Storage Center system. This total includes the disks in the storage system chassis and the disks in the SC100/SC120 expansion enclosures.?The SCv2000 supports up to thirteen SC100 expansion enclosures, up to six SC120 expansion enclosures, or any combination of SC100/SC120 expansion enclosures as long as the total disk count of the system does not exceed 168.

?The SCv2020 supports up to twelve SC100 expansion enclosures, up to six SC120 expansion enclosures, or any combination of SC100/SC120 expansion enclosures as long as the total disk count of the system does not exceed 168.

Storage Center Architecture Options

A Storage Center with an SCv2000/SCv2020 storage system can be deployed in the following configurations:

?An SCv2000/SCv2020 storage system deployed without SC100/SC120 expansion enclosures.

Figure 1. SCv2000/SCv2020 without Expansion Enclosures

?An SCv2000/SCv2020 storage system deployed with one or more SC100/SC120 expansion enclosures.

NOTE: A storage system with a single storage controller cannot be deployed with expansion

enclosures. The storage system must have dual storage controllers to deploy expansion

enclosures.

Figure 2. SCv2000/SCv2020 with Two SC100/SC120 Expansion Enclosures

Storage Center Replication

Storage Center sites can be collocated or remotely connected and data can be replicated between sites. Storage Center replication can duplicate volume data to another site in support of a disaster recovery

10About the SCv2000/SCv2020 Storage System

plan or to provide local access to a remote data volume. Typically, data is replicated remotely as part of an overall disaster avoidance or recovery plan.

The SCv2000 Series Storage Center supports replication to other SCv2000 Series Storage Centers. However, an Enterprise Manager Data Collector must be used to replicate data between the storage systems.

?For more information on installing an Enterprise Manager Data Collector, see the Dell Enterprise Manager Installation Guide.

?For more information on managing the Data Collector and setting up replications, see the Dell Enterprise Manager Administrator’s Guide.

Storage Center Communication

A Storage Center uses multiple types of communication for both data transfer and administrative functions.

Storage Center communication is classified into three types: front end, back end, and system administration.

Front-End Connectivity

Front-end connectivity provides IO paths from servers to a storage system and replication paths from one Storage Center to another Storage Center. The SCv2000/SCv2020 storage system provides the following types of front-end connectivity:

?Fibre Channel: Hosts, servers, or Network Attached Storage (NAS) appliances access storage by connecting to the storage system Fibre Channel ports through one or more Fibre Channel switches.

Connecting host servers directly to the storage system, without using Fibre Channel switches, is not supported.

When replication is licensed, the SCv2000/SCv2020 can use the front-end Fibre Channel ports to replicate data to another Storage Center.

?iSCSI: Hosts, servers, or Network Attached Storage (NAS) appliances access storage by connecting to the storage system iSCSI ports through one or more Ethernet switches. Connecting host servers directly to the storage system, without using Ethernet switches, is not supported.

When replication is licensed, the SCv2000/SCv2020 can use the front-end iSCSI ports to replicate data to another Storage Center.

?SAS: Hosts or servers access storage by connecting directly to the storage system SAS ports.

NOTE: When replication is licensed, the SCv2000/SCv2020 can use the embedded REPL port to perform iSCSI replication to another SCv2000 series Storage Center.

If replication is licensed and the Flex Port license is installed, the SCv2000/SCv2020 can use the embedded MGMT port to perform iSCSI replication to another SCv2000 series Storage Center. In addition, the SCv2000/SCv2020 can use the embedded MGMT and REPL ports as front-end iSCSI ports for connectivity to host servers when the Flex Port license is installed.

About the SCv2000/SCv2020 Storage System11

SCv2000/SCv2020 Storage System with Fibre Channel Front-End Connectivity

An SCv2000/SCv2020 storage system with Fibre Channel front-end connectivity may communicate with

the following components of a Storage Center system.

Figure 3. Storage System with Fibre Channel Front-End Connectivity

12About the SCv2000/SCv2020 Storage System

SCv2000/SCv2020 Storage System with iSCSI Front-End Connectivity

An SCv2000/SCv2020 storage system with iSCSI front-end connectivity may communicate with the

following components of a Storage Center system.

Figure 4. Storage System with iSCSI Front-End Connectivity

About the SCv2000/SCv2020 Storage System 13

SCv2000/SCv2020 Storage System with SAS Front-End Connectivity

An SCv2000/SCv2020 storage system with SAS front-end connectivity may communicate with the

following components of a Storage Center system.

Figure 5. Storage System with SAS Front-End Connectivity

Back-End Connectivity

Back-end connectivity is strictly between the storage system and expansion enclosures, which hold the physical drives that provide back-end expansion storage.

An SCv2000/SCv2020 storage system supports back-end connectivity to multiple expansion enclosures.

14About the SCv2000/SCv2020 Storage System

System Administration

To perform system administration, the Storage Center communicates with computers using the Ethernet management (MGMT) port.

The Ethernet management port is used for Storage Center configuration, administration, and management.

NOTE: The baseboard management controller (BMC) does not have a separate physical port on the SCv2000/SCv2020. The BMC is accessed through the same Ethernet management port that is used for Storage Center configuration, administration, and management.

SCv2000/SCv2020 Storage System Hardware

The SCv2000/SCv2020 storage system ships with Dell Enterprise drives, two redundant power supply/ cooling fan modules, and either one storage controller or two redundant storage controllers.

Each storage controller contains the front-end, back-end, and management communication ports of the storage system.

SCv2000/SCv2020 Storage System Front-Panel Features and Indicators

The front panel of the SCv2000/SCv2020 contains power and status indicators, a system identification button, and a unit ID display.

In addition, the hard drives are installed and removed through the front of the storage system chassis.

Figure 6. SCv2000/SCv2020 Front-Panel View

About the SCv2000/SCv2020 Storage System15

SCv2000/SCv2020 Back-Panel Features and Indicators

The back panel of the SCv2000/SCv2020 contains the storage controller indicators and power supply indicators.Figure 7. SCv2000/SCv2020 Back-Panel View NOTE: Flex Port license is installed.16About the SCv2000/SCv2020 Storage System

SCv2000/SCv2020 Storage Controller Features and Indicators

An SCv2000/SCv2020 storage system includes up to two storage controllers in two interface slots.

SCv2000/SCv2020 Storage System Storage Controller with Fibre Channel Front-End Ports The following figures show the features and indicators on a storage controller with Fibre Channel front-end ports.

Figure 8. SCv2000/SCv2020 Storage System Storage Controller with Four 8 Gb Fibre Channel Front-End Ports

About the SCv2000/SCv2020 Storage System17

Figure 9. SCv2000/SCv2020 Storage System Storage Controller with Two 16 Gb Fibre Channel Front-End Ports

18About the SCv2000/SCv2020 Storage System

SCv2000/SCv2020 Storage System Storage Controller with iSCSI Front-End Ports

The following figures show the features and indicators on a storage controller with iSCSI front-end ports.Figure 10. SCv2000/SCv2020 Storage System Storage Controller with Four 1 GbE iSCSI Front-End Ports About the SCv2000/SCv2020 Storage System 19

Figure 11. SCv2000/SCv2020 Storage System Storage Controller with Two 10 GbE iSCSI Front-End Ports

20About the SCv2000/SCv2020 Storage System

SCv2000/SCv2020 Storage System Storage Controller with SAS Front-End Ports

The following figure shows the features and indicators on a storage controller with SAS front-end ports.Figure 12. SCv2000/SCv2020 Storage System Storage Controller with Four 12 Gb SAS Front-End Ports About the SCv2000/SCv2020 Storage System 21