Data Sheet

SS/MAG/WW

Issue 20

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

Industry-specific design

–suitable for all applications found in the water and waste water industries

Widest flow range, highest accuracy

–diameters from 15mm to 2200mm (0.5 to 84 in.) Submersible sensor

–suitable for flooded chambers and pits Buriable sensor

–eliminates chambers and ensures fast, low-cost installation Hazardous area approvals

–FM,CSA,ATEX

–ideal for waste water treatment works Built-in earthing (grounding) electrode

–eliminates the need for earthing (grounding) flanges 2-year warranty as standard

–high-quality product guarantees reliable maintenance-free operation CalMaster compatible

–in situ verification of flow meter calibration Remote communications

–including Profibus DP v0

MagMaster – bringing unsurpassedflowmetering performance to the

Water and Waste Water industries

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

SS/MAG/WWIssue 20

Setting the Standard

Designed specifically to target the diverse applications found inthe supply and treatment of both potable and waste water,MagMaster sets new levels of accuracy, reliability and low costof ownership.

MagMaster's ground-breaking design guarantees long-termcalibration stability, coupled with the wide range of sizes, 15 to2600mm (0.5 to 102 in.), choice of lining and electrode materialquickly established MagMaster as the de facto industrystandard electromagnetic flow meter.

Calibration Verification

CalMaster is the world's first in situ calibration verificationsystem. The system allows the calibration of MagMasterelectromagnetic flow meters to be verified without the need for'wet calibration'. The complex series of tests automaticallyperformed by CalMaster is completed and a certificateproduced without costly excavation of the sensor or disruptionto the water supply. A complete solution to the regulatoryrequirement for routine verification and traceability ofelectromagnetic flow meters.

Class-leading Flow Performance

The combination of sensors with ultra-linear magnetics, proventechnology, signal processing and sensor drive results inunsurpassed accuracy and an operable flow range of 1500:1.MagMaster's class-leading performance ensures reliable andaccurate measurement over the widely varying flow rates,including minimal night flows, which occur in typical water andwaste water systems.

Assured Quality

MagMaster is designed and manufactured in accordance withinternational quality procedures (ISO 9001) and all flowmetersare calibrated on nationally-traceable calibration rigs to providethe end user with complete assurance of both quality andperformance of the meter.

For further information on CalMaster refer to the brochurePB/CALMASTER

ABB operated national and internationally accredited flow calibration facilities in the UK, USA, Australia, Germany and India.

2

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

SS/MAG/WWIssue 20

Electronic Display Unit

Comprehensive display Forward, reverse and net totals

4 digital outputs: forward pulse, reverse pulse, alarm 1

and alarm 2 2 analog outputs (output 2 optional)

Communications: serial data (RS232), HART and

ProfibusDP v0MagMaster is available with integral or remote transmitters,configuration is achieved either with a configurator of via theoptional integral keypad. The software features multi-levelpassword protection to prevent unauthorized configurationchanges. In the 2-line display only variant, display data can onlybe changed using a magnetic wand, no operational parameterscan be changed without the use of a configurator andappropriate passwords.

Wallmount Version

Programming Options

Local hand-held configurator (for example Psion

Workabout) Integral keypad HART

Personal computer

3

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

SS/MAG/WWIssue 20

Easy, Low-cost Installation

MagMaster sensors' rugged and robust construction ensure along, maintenance-free life under the arduous conditionsexperienced in the water and waste water industry. The sensorsare fully submersible, meeting the requirements of IP68(NEMA6P) enabling installation in flooded chambers or meteringpits.

MagMaster sensors in all sizes are buriable. Installation merelyinvolves excavating to the underground pipe, fitting the sensor,cabling back to the transmitter and then backfilling the hole. Nometering chambers or pits are required so the installation issimple, fast and low cost.

Underground Installation of MagMaster

International Approvals

Alternative versions of MagMaster are available for generallocations with FM Approval and for Hazardous Area locations toATEX, FM and CSA Standards. A brief summary of theseHazardous Area versions is given below, covering the safetydesignation inside the pipe. No external safety barriers arerequired.

SENSORINSIDE PIPETRANSMITTER LOCATION

FM & CSA HAZARDOUS AREA APPROVAL – CLASS 1, DIV. 2, GROUPS A B C DFM APPROVED

INTRINSICALLY SAFE ELECTRODES

CSA CERTIFIEDCSA CERTIFIED

NON INCENDIVE

REMOTE ONLY IN HAZARDOUS AREA

INTEGRAL AND REMOTE IN HAZARDOUS AREAREMOTE ONLY IN HAZARDOUS AREA

ATEX — II 2 (i) G EEx e m ia IIC T4ZONE 1

ZONE 0

REMOTE TRANSMITTER IN SAFE AREA

4

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

SS/MAG/WWIssue 20

Specification

Sensor

Sizes

Flow Range

Sizes mm (in.)

Minimumm 3/h (US g/min)

15 (0.6)20 (0.8)25 (1)40 (1.6)50 (2)65 (2.5)80 (3)100 (4)150 (6)200 (8)250 (10)300 (12)350 (14)400 (16)450 (18)500 (20)600 (24)700 (28)760 (30)800 (31)900 (35)1000 (39)1050 (41)1200 (47)1400 (55)1500 (59)1600 (63)1800 (71)2000 (79)2200 (87)

0.005 (0.021)0.009 (0.038)0.014 (0.059)0.035 (0.15)0.053 (0.23)0.089 (0.40)0.136 (0.59)0.21 (0.94)0.47 (2.10)0.84 (3.73)1.32 (5.83)1.91 (8.4)2.60 (11)3.39 (15)4.29 (19)5.3 (23)7.6 (33)14 (46)16 (52)

18 (60)23 (75)28 (93)31 (112)41 (134)55 (182)64 (208)72 (238)92 (302)113 (372)136 (451)

Maximum*m 3/h (US g/min)

Accuracy (under forward flow reference conditions)

6 (28)11 (50)17 (77)45 (197)71 (311)119 (525)181 (796)283 (1243)640 (2797)1130 (4974)1770 (7771)2540 (11190)3460 (15230)4520 (19890)5730 (25180)7070 (31090)10180 (44760)13850 (60920)15900 (69930)18100 (79560)22900 (100700)28300 (124300)34200 (150400)40700 (179000)55400 (243700)63600 (279700)72400 (318300)91600 (402800)113100 (497400)137000 (602000)

* Based on 10ms–1 (33fts–1), but instrument capability in excess of 15ms–1 (50fts–1)

5

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

SS/MAG/WWIssue 20

Wetted Material

Lining

Suitable for potable water and waste water(all materials UKWFBS listed and compliant to WRC Water Bye-laws Scheme BS 6920)Contact factory for non-standard materialsElectrodes

Stainless steel 316

Contact factory for non-standard materialsFlanges

Carbon steel

Pressure limitations

≤600mm as flange rating≥700mm 6, 10 or 16 barEnvironmental protectionIP68 (NEMA6P)Buriable to 5m (16 ft) depth

Pressure equipment directive 97/23/EC

This product is applicable in networks for the supply, distribution anddischarge of water and associated equipment and is thereforeexempt.Conductivity≥5µS/cmEnd connectionsPN6PN10PN16

ANSI B16.5 Class 150

ANSI/AWWA C207 Class B and D

AS2129 Table C or BS10/AS2129 Table D and E

Electronic Display Unit

Mounting

Integral with sensorOR

Remote up to 100m (325 ft)

Longer lengths available on requestHousing

IP65 (NEMA4)

Glass-loaded polypropylene, polycarbonate window ULVO ratedElectrical connections20mm glands, or accepts

1/2 in. NPT connections

Sensor cable

ABB cable supplied as standardArmored version available on request

Power supply*

Voltage Type

ACDC

Voltage Range (V) Absolute rating

85 to 26511 to 40

Frequency (Hz)47 to 440

VA<20<20

*Power supply fully isolated

Liquid Sensing

Drives output to zero with an empty pipe

Languages

Operation in English, French, German, Spanish, Italian, Dutch plusothers on application

Temperature Ranges

6

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

SS/MAG/WWIssue 20

Output/Inputs

Mounting

Pipe Connections

7

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

SS/MAG/WWIssue 20

Sensor Specification (nominal dimensions)

15 to 2200mm (0.5 to 84 in.)

Meter Size mm

15202540506580100150200250300350400450500600700760800900100010501200140015001600180020002200

*Typical tolerance +0/–3mm**Typical tolerance +0/–5mm***Typical tolerance +0/–10mm

Flange Size

Metric Flanges (DN)

15202540506580100150200250300350400450500600700760800900100010501200140015001600180020002200

BS10 Flanges (in.)

1/23

AWWA C207 Flanges (NPS)

1/23

Length A mm (in.)

Approximate Weight

kg (lb)

/4/47 (15)

111/2221/23468101214161820242730–36394248546066727884

111/2221/23468101214161820242830–36394248546066727884

250 (9.8)*300 (11.8)*350 (13.8)**450 (17.7)**500 (19.7)**550 (21.7)**600 (23.6)**698 (27.5)**768 (30.2)**918 (36.1)**700 (27.6)***762 (30)***800 (31.5)***900 (35.4)***1000 (39.4)***1067 (42)***1200 (47.2)***1400 (55.1)***1524 (59)***1600 (63)***2250 (88.6)***2500 (98.4)***2750 (110)***

540 (1190)720 (1585)880 (1930)1000 (2160)1450 (3190)1370 (3000)2000 (4400)2400 (5280)3200 (7040)4200 (9300)430 (945)

200 (7.9)*

9 (20)10 (23)18 (40)18 (40)24 (54)38 (84)55 (121)88 (194)128 (282)100 (220)115 (253)160 (352)217 (455)315 (693)

8

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

SS/MAG/WWIssue 20

Overall Dimensions

Terminal Box – Sensor Mounted

IP65/NEMA4 Remote Electronic Display Unit

9

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

Integral Electronic Display Unit (mounted on Sensor)

SS/MAG/WWIssue 20

10

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

SS/MAG/WWIssue 20

Electrical Connections

11

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

SS/MAG/WWIssue 20

Ordering Information

Sensor Ordering Code Calibrated Bore

No sensor (Transmitter only)15mm (1/2 in.)20mm (3/4 in.)25mm (1 in.)40mm (11/2 in.)50mm (2 in.)65mm (21/2 in.)80mm (3 in.)100mm (4 in.)150mm (6 in.)200mm (8 in.)250mm (10 in.)300mm (12 in.)350mm (14 in.)400mm (16 in.)450mm (18 in.)500mm (20 in.)600mm (24 in.)700mm (28 in.)760mm (30 in.)800mm (31 in.)900mm (35 in.)1000mm (39 in.)1050mm (41 in.)1200mm (47 in.)1400mm (55 in.)1500mm (59 in.)1600mm (63 in.)1800mm (71 in.)2000mm (79 in.)2200mm (87 in.)

≥2400mm (94 in.) – apply to Sales OfficeEnd Connections – Flanged

None (Transmitter only)PN16, fully rated

PN16, 10 bar rated 700mm to 2200mmPN16, 6 bar rated 700mm to 2200mmPN10, fully rated

PN6, fully rated 700mm to 2200mm

ANSI B 16.5 class 150, fully rated ≤24 in.

ANSI/AWWA C207 class B fully rated 27 in. to 66 in.ANSI/AWWA C207 class D fully rated 27 in. to 66 in.AS2129 Table C fully rated ≤24 in.AS2129 Table D fully rated ≤66 in.

BS10/AS2129 Table E, fully rated ≤48 in.BS10 Table D fully rated ≤66 in.AS4087 Class 16

01CB583UVFL7KZ

E000E150E200E250E400E500E650F800F101F151F201F251F301F351F401F451F501F601F701F761F801F901F102F112F122F142F152F162E182E202E222MF

XXXX

X

X

X

X

X

XX

X

XX

12

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

SS/MAG/WWIssue 20

Sensor Ordering Code MFXXXXXXXX0XXXXXX

Lining Material

None (Transmitter only)

Elastomer suitable for potable water and waste water – WRAS (UK) Listed

Elastomer suitable for potable water and waste water – ACS (France) ApprovedOthers on applicationElectrodes

None (Transmitter only)

316 Stainless Steel (suitable for water and waste water)Others on applicationSensor Build Standard

Transmitter onlyGeneral

FM – GENERALCalibration

Transmitter only

Standard 3-point, with pressure test8-point, with pressure testUKAS, with pressure test

Standard 3-point, no pressure test8-point, no pressure testUKAS, no pressure test

Standard 3-point; CalMaster Fingerprint & disk; No pressure testStandard 3-point; CalMaster Fingerprint & disk; With pressure test

Cable Length – User-specified length in 10m increments (90m max.) (Must be '00' for glanding digit 4)Glanding

None (Transmitter only)

20mm plastic gland (sensor cable fitted and potted)

Conduit entry: 1/2 in. NPT (Blanked) – all North American versions (cable length to be '00')20mm plastic. Cable not fitted.20mm armor. Cable not fitted.Transmitter

Sensor-mounted MagMaster Transmitter, ≤400mm (16 in.) onlyRemote MagMaster Transmitter

EHER01457

0125ABDIJ

XX

0180104F

13

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

SS/MAG/WWIssue 20

Transmitter Ordering CodePower Supply

None - Sensor only

95V to 240V AC nominal, 47 to 440Hz11V to 40V DC (Max)Display

None (or sensor only)2-Line Display

3-Line Display with keypad (no HART)Output Options

Standard outputs (or sensor only)Dual current outputHART communicationsProfibus DP v0

Transmitter Build Standard

Transmitter onlyGeneral

FM – GENERALDisplay Orientation

None (or sensor only)Standard

Other please enquireLanguage

None (or sensor only)EnglishFrenchGermanSpanishItalianDutchLabelling

Factory allocated (internal only)

XXXXXXX

013

034

0128

013

01

0123456

X

14

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

SS/MAG/WWIssue 20

15

Electromagnetic Flowmeter

MagMaster – Water & Waste Water Version

ABB has Sales & Customer Support expertiseThe Company’s policy is one of continuous productin over 100 countries worldwide improvement and the right is reserved to modify the

information contained herein without notice.

Printed in UK (04.09)

© ABB 2009

ABB Limited

ABB Inc.

Oldends Lane, Stonehouse125 E. County Line RoadGloucestershireWarminsterGL10 3TAPA 18974UK

USA

Tel:+44 (0)1453 826661Tel:+1 215 674 6000Fax:+44 (0)1453 829671Fax:+1 215 674 7183

Issue 20SS/MAG/WW