Precision Hot Air Station

Ref. TE-C

本说明书由汉迪丰科技-黄新银整理

JBC会不定时对产品进行升级改动,因此型号也会有所变动,最新型号请联系发布人sales6@handif.com

TE是一款精密高效能热风机,用於快速安全地焊接/拆焊各类型中小型SMD电子元件。 TE有两种工作模式 - 手动作业和参数设置自动控制,这能有效地管理温度和热风流量。它是可以经由功能表自行设置更多的功能参数。 TE精密高效热风工作站配有TE加热器及所有 必要配件,如三脚架丶回流风罩及自动提取器, 这些配件可以使您的工作更加方便。

它也包含自动提取器放置台和一个快速更换热风头的加热柄焊具座。

此版本现提供 USB接口 (B型接口), 未来可连接电脑进行软体升级及提供即时温度/功率曲线。

技术资料

重量 5.4 kg (11.9 lb)

尺寸 See individual modules 电压 230V / 120V / 100V

保险丝 4A (230V), 8A (120V and 100V) 输出功率 300W

温度选择范围 Tamb-450 oC / Tamb-850 oF 工作环境温度 10-40 oC / 50-104 oF 温度波动范围 +/-20 oC / +/-36 oF 防静电 热风风量 4-11 SLPM 包装重量 6.5 kg (14.2 lb) 包装尺寸 475x370x200 mm

Packing List

The following items should be included: JTE Control Unit ............1 unit Ref. JTE-1C

JTE-2C JTE-9C

Stand ..................................1 unit Ref. TE-SA

Precision Heater

hose set ............................1 unit Ref. TE-TB

Extractor desk* ..............................................1 unit Ref. 0008752

Accessory set Ref. 0012332

Extractors* Ref. E2184 E2064 E2052 Tripod* Ref. T2050 T2250

Protectors* Ref. P2220 P2230 P2235 P4000 P4010 Suction Tube* Ref. 0932330

Power Cord .....1 unit Ref. 0009417

(100V/120V) 0009401 (230V)

Manual .............1 unit Ref. 0015898 Suction Cups* Ref. 0930110 ? 10 - 0934050 (x3) ? 4.7 - 0934070 (x1) Nozzles Ref. TN9209 ? 3mm TN9208 ? 4mm TN9080 ? 5mm www.jbctools.comPrecision Hot Air Station

Ref. TE-C * Not supplied with TE-QC

2

3

Features

USB-B connector Update the station software from the JBC website

Adjustable Stand Nozzle Changer

Suits your work position Nozzle changer 1 2

Activates the suction pump

Precision Heater Hose set Ref. TE-TB

Suction Tube Ref. 0932330 For tripods and extractors

Heating element

Compatible Nozzles

The TE-TB works with TE nozzles. Find the model that best suits your soldering needs in www.jbctools.com

Straight

? mm

? mm

Bent

Other connectable tool: Heater hose set Ref: JT-TA

Hot Air switch (On / Off)

Ref.

Shape Size

To Pedal Ref. P-005

Press the pedal to start hot air or release to stop. Power Socket Fuse

TN9209 Straight TN9208 Straight TN9080 Straight TN9787 TN9785 TN9782 Bent Bent Bent ? 3mm ? 4mm ? 5mm ? 3mm ? 4mm

Equipotential connection

? 5mm

4

5

Protectors & Extractors Operation

For large components (fig. 3 and 4). We recommend using the extractors

3

4

For small components (fig. 1 and 2).

We recommend using the protector + tripod

1. Placing 2. Heating 3. Releasing

1 2

Protectors

Extractors

Position the extractor with the appropriate suction cup and press the suction button.

Heat the component by pressing the heater button.

The component lifts off automatically when the solder melts.

* Ref. AxB (mm) * Ref. AxB (mm)

48 P2230 15 x 15 60 P4010 17 x 17 * Ref. AxB (mm)

52 E2052 20 X 20 64 E2064 20 X 26 80 E2184 24 X 24 * Ref. AxB (mm)

P3353 4,3 x 3 P3786 5,2 x 5,2 P3352 5,2 x 7,5 P3355 5,2 x 9,5 P3356 6,2 x 4,2 P3785 7,2 x 7,2 P3784 8,2 x 8,2 P4035 9 x 13 P4040 9,5 x 19 P4080 9,5 x 21 E2124 45 X 45

P4005 18 x 29 P4030 18,5 x 18,5 P1068 18,5 x 24 P2685 28,5 x 28,5 P4085 31,5 x 31,5 P2672 33 x 46 P4002 50 x 50 P3357 52,5 x 14 Process Control

Manual Mode

E2068 27 X 27 E4020 28,5 X 28,5 E4015 31,5 X 31,5 E2084 33 X 33 E2100 38 X 38

Current temperature 32 P2220 10 x 10

Tripods

* Ref. ?C (mm) T2050 39 T2250 85 Selected temperature P4045 10,5 x 21 P4090 11 x 16 400oC Select Power 70% 400 85 Time to stop 45 seconds Temp oC Air Current air flow

24 P2235 12 x 17 % Instant power supplied to heater

P1249 12 x 23 44 P4000 12,5 x 12,5

P3354 13,2 x 13,2 P4025 13,5 x 21,5 * Reference Desk Manual extractor * Ref. ?D (mm) Access Menu (pess key 2 seconds) & Confirm Selection

6

E2190 7 You can switch between operating modes (Manual Mode / Program Mode) by pressing the “increase” and “decrease” keys simultaneously for 2 seconds (Only when programs mode is ON).

? D 7

Program Mode

Original PIN: 0105

Menu Screen

oC Graph of selected

program

Program 8 Temp oC Selected program Current temperature Selected air flow

Remaining time

Main menu Air 100% Time 125s. 380 1 2 3 4 5 Reset settings Station Settings Program Settings Counters Program version Exit Decrease program

number

Increase program number

Settings Program Sett ngs

Edit Program

This option allows you to edit or create a program.

First, you must select the program to edit and then modify the points that make up the program. Each program is composed of 9 points, each point consisting of 3 parameters:

1. Time (seconds) 2. Temperature (°C / °F) 3. Flow rate (%)

1 Temp unit Celsius 2 Maximum temp 4500C T OFF* 3 Minimum temp 4 Fix temp 4000C 5 Temp Adjust 6 Max air 7 Min air 8 Fix air 9 Time to stop 10 Beep 11 Pop up 12 Change PIN

1 2 3 4 Programs Edit program Copy program Delete program 00C 100% 10% 40% 120 sec ON ON oC Ed t Program Select Program

You can delete the last point of the program by selecting “-----” in the time parameter. Remember that the regulation range permitted by the station is between 150°C and 450°C, so it is not possible to create temperature ramps between room temperature ( T OFF ) and 150°C.

8 oC dit Program

The station can store up to 25 temperature programs. The first three programs are installed as an example.

ack

* Selecting Minimum Temp as “T OFF”, the air blows at room temperature.

Copy Program

This option allows you to copy a program.

You must select the program source and its destination (where it will be copied).

Step 4 Time 20 Temp 450 Air 100 Exit

Delete Program

This option will allow you to delete a previously selected program.

Counters 1 Station ON hours 2 Works hours 3 Works cycles ack 0 0 0 8

9

Replacing the Heating Element

Pick & Place (not supplied with TE)

This tool helps you easily place and remove SMDs of any size thanks to the suction pump.

Pick & Place Ref. T260-A

Bent Needles Set Ref. 0861660

Straight Needles Set

Ref. 0901546

Only perform this operation when the element is cold and the unit is disconnected from the mains.

1. Loosen the screw.

2. Pull the heating element away from the handle.

3. Connect the new heating element, ensuring it is pushed all the way in. 4. Tighten the screw.

Heating Element Ref. 0012374 (100V - 230V - 120V)

Handle

Ref. 0012697

Precision Heater Hose Set Ref. TE-TB

Operation

Choose the needle and the suction cup that best fits the component and start working as follows:

Press the button to start/stop the suction

Changing the TE-TB Precision Heater Hose Set

Pick & Place Ref. T260-A

1. Ensure that the tool is turned off.

2. Use a spanner to unscrew the connecting nut. 3. When attaching the new tube make sure the rib lines up with the groove on the control unit. 4. Tighten with the spanner.

1. Suction

Maximum working temp: 250oC (482oF) Insert the needle with the appropriate cup for a correct suction process.

You should avoid the needle protruding from the lower part.

Once the suction is activated, cover the pen hole with your finger and lift off the component.

2. Release

Lift your finger to release the component in the appropriate place.

10

11

Maintenance Safety

It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.

- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire.

Before carrying out maintenance or storage, always allow the equipment to cool.

- Clean the station screen with a glass cleaner or a damp cloth.

- Use a damp cloth to clean the casing and the tool. Alcohol can only be used to clean the metal parts.

- The power cord must be plugged into approved bases. Be sure that it is properly grounded before use. When unplugging it, hold the plug, not the wire.

- Maintain heating element clean prior to storage in order to avoid its oxidation. Rusty and dirty surfaces reduce heat transfer.

- Do not work on electrically live parts.

- Periodically check all cables and tubes.

- The tool should be placed in the stand when not in use in order to activate the sleep mode.

The soldering tip, the metal part of the tool and the stand may still be hot even when the station is turned off. Handle with care, including when adjusting the stand position.

- Replace a blown fuse as follows:

- Do not leave the appliance unattended when it is on.

Fuse

- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.

- Use a “non residue” classified flux and avoid contact with skin or eyes to prevent irritation.

- Be careful with the fumes produced when soldering.

Fuse holder

Fuse holder - Keep your workplace clean and tidy. Wear appropriate protective glasses and gloves when working to avoid personal harm.

- Utmost care must be taken with liquid tin waste which can cause burns.

1. Pull off the fuse holder and remove the fuse. If necessary use a tool to lever it off.

2. Press the new fuse into the fuse holder and replace it in the station.

- This appliance can be used by children over the age of eight and also persons with reduced

physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved. Children must not play with the appliance.

- Replace any defective or damaged pieces. Use original JBC spare parts only.

- Maintenance must not be carried out by children unless supervised.

- Repairs should only be performed by a JBC authorized technical service.

12

13

Specifications Exploded View

TE-1C 120V 50/60Hz. Input fuse 8A. Rated Current 6A. Control Unit model: JTE-1C TE-2C 230V 50/60Hz. Input fuse 4A. Rated Current 3A. Control Unit model: JTE-2C TE-9C 100V 50/60Hz. Input fuse 8A. Rated Current 7A. Control Unit model: JTE-9C - Weight: 5.2 kg (11.4 lb)

- Dimensions: 148 x 184 x 140 - Nominal Power: 300W

- Temperature selection: Room temperature / 150oC to 450°C (300oF to 840oF) Cool mode: T Off. Used to blow air at room temperature - Ambient Operating Temperature: 10 to 40oC (50-104oF) - Idle Temp. Stability: +/-20 oC (+/-36 oF) - Air flow regulation: 3-17 SLPM - USB connector station-PC - P-005 Pedal connector

Complies with CE standards

ESD protected housing “skin effect”

14

15

Warranty

JBC’s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour.

Warranty does not cover product wear due to use or mis-use.

In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.

This product should not be thrown in the garbage.

In accordance with the European directive 2002/96/EC, electronic equipment at the end of their life must be collected and returned to an authorized recycling facility.