InGaN RoHS 2.0 CAN14-203371-03_EC_F

更新时间:2023-04-18 11:59:01 阅读量: 实用文档 文档下载

说明:文章内容仅供预览,部分内容可能不全。下载后的文档,内容与下面显示的完全一致。下载之前请确认下面内容是否您想要的,是否完整无缺。

Test Report No. CANEC1420337103 Date: 09 Dec 2014Page 1 of 8ANHUI SANAN OPTOELECTRONICS CO.,LTD.NO.8 DONGLIANG ROAD,ECONOMIC&TECHNOLOGICAL DEVELOPMENT AREA,WUHU CITY,ANHUI The following sample(s) was/were submitted and identified on behalf of the clients as : InGaN SGS Job No. :

XM15793101EC - XM Date of Sample Received :25 Nov 2014Testing Period :25 Nov 2014 - 06 Dec 2014Test Requested :Selected test(s) as requested by client.Please refer to next page(s).Please refer to next page(s).Test Method :Test Results :Conclusion :Based on the performed tests on submitted sample(s), the results of Lead,

Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs),

Polybrominated diphenyl ethers (PBDEs) comply with the limits as set by RoHS

Directive 2011/65/EU Annex II; recasting 2002/95/EC.Signed for and on behalf of

SGS-CSTC Ltd.Alkene_Liang .

Approved Signatory

Test Report No. CANEC1420337103 Date: 09 Dec 2014Page 2 of 8Test Results :Test Part Description :.Specimen No.SGS Sample ID Description SN1CAN14-203371.001Khaki particle Remarks :(1) 1 mg/kg = 1 ppm = 0.0001%(2) MDL = Method Detection Limit (3) ND = Not Detected ( < MDL )(4) "-" = Not Regulated RoHS Directive 2011/65/EU .

Test Method :(1)With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES.

(2)With reference to IEC 62321-5:2013, determination of Lead by ICP-OES.(3)With reference to IEC 62321-4:2013, determination of Mercury by ICP-OES.

(4)With reference to IEC 62321:2008, determination of Hexavalent Chromium by Colorimetric Method using UV-Vis.

(5)With reference to IEC 62321:2008, determination of PBBs and PBDEs by GC-MS.001.

Cadmium (Cd)100mg/kg 2ND Lead (Pb)1,000mg/kg 2ND Mercury (Hg)1,000mg/kg 2ND Hexavalent Chromium (CrVI)1,000mg/kg 2ND Sum of PBBs 1,000mg/kg -ND Monobromobiphenyl -mg/kg 5ND Dibromobiphenyl -mg/kg 5ND Tribromobiphenyl -mg/kg 5ND Tetrabromobiphenyl -mg/kg 5ND Pentabromobiphenyl -mg/kg 5ND Hexabromobiphenyl -mg/kg 5ND Heptabromobiphenyl -mg/kg 5ND Octabromobiphenyl -mg/kg 5ND Nonabromobiphenyl -mg/kg 5ND Decabromobiphenyl -mg/kg 5ND Sum of PBDEs 1,000mg/kg -ND Monobromodiphenyl ether -

mg/kg 5

ND

Test Item(s).

Limit .

Unit .

MDL

.

Test Report No. CANEC1420337103 Date: 09 Dec 2014Page 3 of 8

Test Item(s).Limit.Unit.MDL.001.

Dibromodiphenyl ether-mg/kg5ND

Tribromodiphenyl ether-mg/kg5ND Tetrabromodiphenyl ether-mg/kg5ND Pentabromodiphenyl ether-mg/kg5ND Hexabromodiphenyl ether-mg/kg5ND Heptabromodiphenyl ether-mg/kg5ND Octabromodiphenyl ether-mg/kg5ND Nonabromodiphenyl ether-mg/kg5ND Decabromodiphenyl ether-mg/kg5ND

Notes :

(1) The maximum permissible limit is quoted from the directive 2011/65/EU, Annex II. Hexabromocyclododecane (HBCDD).

Test Method :Determination of HBCDD by GC-MS based on IEC 62321:2008.

Test Item(s).Unit.MDL.

mg/kg 001.

10ND Hexabromocyclododecane (HBCDD)

Notes :

(1) Reference Information: Directive 2011/65/EU recasting RoHS directive 2002/95/EC:

Hexabromocyclododecane (HBCDD) is considered as a priority for risk evaluation and substance restriction.

Phthalate.

Test Method :Determination of phthalates by GC-MS based on EN 14372:2004.

CAS NO.

Test Item(s).Unit.MDL.001.

Dibutyl Phthalate (DBP)84-74-2%(w/w)0.003ND

Benzylbutyl Phthalate (BBP)85-68-7%(w/w)0.003ND

Bis(2-ethylhexyl) Phthalate

(DEHP)

117-81-7%(w/w)0.003ND

Test Report No. CANEC1420337103 Date: 09 Dec 2014Page 4 of 8

Notes :

(1) Reference Information: Directive 2011/65/EU recasting RoHS directive 2002/95/EC:

Bis (2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP) and Dibutyl phthalate (DBP) are considered as a priority for risk evaluation and substance restriction.

Remark: Results & photo(s) of this report refer to test report CANEC1420337101.

Test Report No. CANEC1420337103 Date: 09 Dec 2014Page 5 of 8

ATTACHMENTS

RoHS Testing Flow Chart

1) Name of the person who made testing: Bruce Xiao / Sunny Hu

2) Name of the person in charge of testing: Bella Wang / Cutey Yu

3) These samples were dissolved totally by pre-conditioning method according to below flow chart

(Cr6+ and PBBs/PBDEs test method excluded).

Test Report No. CANEC1420337103 Date: 09 Dec 2014Page 6 of 8

ATTACHMENTS

HBCDD Testing Flow Chart

1) Name of the person who made testing: Sunny Hu

2) Name of the person in charge of testing: Cutey Yu

Test Report No. CANEC1420337103 Date: 09 Dec 2014Page 7 of 8

ATTACHMENTS

Phthalates Testing Flow Chart

1) Name of the person who made testing: Sunny Hu

2) Name of the person in charge of testing: Cutey Yu

Test Report No. CANEC1420337103 Date: 09 Dec 2014Page 8 of 8 Sample photo: