ABOUT THE NORCROSS SHELL CUP VISCOMETERThe Shell Cup is a simple, reliable device for measuring the viscosity of a wide range of fluids. Originally developed for use with printing inks, it has found widespread applications as diverse as fuel oil and industrial finishes— for calibrating other viscosity sensors as well as for primary measurements. The cup was developed by Shell Development Company and is marketed by Norcross Corporation.
Viscosity Measurement with The Shell Cup The conversion table indicates the useful range for each size. The measurement is accomplished as follows: 1. Submerge the cup in the fluid for approximately 30 seconds to allow the cup to come to sample temperature. The sample must be representative— thoroughly stirred for example, and at a known, preferably standard temperature. 2. Lift the cup vertically out of the fluid, starting the stop-watch as the cup breaks the surface. 3. Record the time required for the cup to empty, stopping the watch when the stream breaks. 4. Read the viscosity from the appropriate conversion charts or calibration drawings. Email us for rmore information.
Product Overview& Viscosity Conversion TablesViscosity Sensors Viscosity Controllers
ABOUT PROCESS VISCOSITY MEASUREMENT AND CONTROLNORCROSS has been measuring the viscosity of numerous different processes for over 60 years. As shown on the front of this conversion table, we have sensors for measuring viscosity in open tanks, closed tanks, pressurized tanks and inside pipe lines. We can measure viscosity at different pressures, flows, temperatures and viscosity ranges. The VISC6000 is a multiple station control system. The MP2000 is a single station controller/transmitter and the MP2500 a single station controller. VISC6000 Touch Screen PLC
ABOUT NORCROSS SENSITIVITY AND ACCURACYThe 24hr circular chart, shown here, is an actual recording obtained with NORCROSS Viscometer. This recording starts with boiling water 212°F/ 100C, which is then allowed to cool. The viscosity was recorded every three minutes during the cooling period. A few measured temperatures, together with corresponding centipoise viscosities, obtained from tables published by the Bureau of Standards, are shown. This chart illustrates the outstanding sensitivity of the NORCROSS Falling Piston Viscometer. This sensitivity, which only the NORCROSS Process Viscometer can produce, combined with the simplicity and ruggedness of all NORCROSS units, create a versatile and long lasting viscosity sensor/system. NORCROSS Viscosity Sensors and/or Viscosity Control Systems are designed to provide years of reliable operation.04_Viscosity Conversion Table 8.2.288ºF/31ºC .782cps 100ºF/37.7ºC .684cps 70ºF/21ºC .979cps
In-Tank Sensors: Model M8BO and M8B (0.1-100,000 cps)
In-Tank Sensor: Model MXBO (0.1-100,000 cps)
True In-Line Sensor: Model M50 (0.1-2,000 cps)
MP2000 Digital Controller
141ºF/60.5ºC .465cps 176ºF/80ºC .361cps 212ºF/ 100ºC.284cps
MP2500 Digita
l Controller64ºF/17.7ºC 1.061cps
58ºF/14.4ºC 1.159cps
Efflux CupShell Cup Viscometer For hand testing viscosity in open tanks/containers. (1-1200 cps) In-Line Sensor: Model M24 (0.1-7,000 cps) Reactor/ In-Line Sensor: Model M20 (1,000 - 1M cps) Reactor Sensor: Model M10 (1-1M cps) Other cups available within range 0.3 cps-7,000 cps
NORCROSS Corporation 255 Newtonville Avenue Newton, MA 02458 Telephone 617 969 7020 Fax 617 969 3260 Email sales@http://www.77cn.com.cn
USA On the Internet http://www.77cn.com.cn
多种涂料用粘度杯数据对照表
VISCOSITYCONVERSIONTABLES by NORCROSS CORPORATION
®
visit us at:255 Newtonville Avenue, Newton, MA 02458 USA Phone: 617.969.7020 Fax: 617.969.3260 Email: sales@http://www.77cn.com.cn
CENTIPOISE1.00 2.00 3.00 5.00 7.50 10.0 15.0 20.0 25.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100 125 150 175 200 225 250 275 300325 350 375 400 500 600 700 800 900 1000 1250 1500 1750 2000 2500 3000 3500 4000 4500 5000 6000 7000 8000 9000 10K References
Notes:
Note 1: This data is based upon a table from Worthington Pump,1956 which was based upon original test data no longer available. Notall ‘Zahn’ Cups match this data.Note 2: This data is based upon original mechanical design of ShellChemical. Equations in ASTM 4212 do not match actual values, asthey were based upon prior data plots that are no longer available anddo not match the actual cups.
Note 3: The 2 1/2 and 3 1/2 Shell Cup were introduced by Norcrossin the 1970’s to provide additional viscosity range coverage.
Note 4: Typical piston size recommended for use in the Model M8BOprocess viscometer ( with a length code C - other lengths may require
different pistons ) - Contact Norcross for information.Note 5: Data based on S.G. =1.0
Centipoise = Centistokes X S.G.
正在阅读:
多种粘度杯对照表08-29
2012武术套路规则和裁判法-表格04-14
尽调清单-针对特定公司的版本06-09
医学免疫学考试复习要点04-29
故障诊断复习题11-06
【人教部编版】五年级语文上册《忆读书》 优质课教学设计08-01
人蚊大战作文600字07-14
蚕宝宝成长记作文450字06-24
描写三月的优美句子 三月的句子唯美大全03-16
六年级数学公开课教案05-21
- exercise2
- 铅锌矿详查地质设计 - 图文
- 厨余垃圾、餐厨垃圾堆肥系统设计方案
- 陈明珠开题报告
- 化工原理精选例题
- 政府形象宣传册营销案例
- 小学一至三年级语文阅读专项练习题
- 2014.民诉 期末考试 复习题
- 巅峰智业 - 做好顶层设计对建设城市的重要意义
- (三起)冀教版三年级英语上册Unit4 Lesson24练习题及答案
- 2017年实心轮胎现状及发展趋势分析(目录)
- 基于GIS的农用地定级技术研究定稿
- 2017-2022年中国医疗保健市场调查与市场前景预测报告(目录) - 图文
- 作业
- OFDM技术仿真(MATLAB代码) - 图文
- Android工程师笔试题及答案
- 生命密码联合密码
- 空间地上权若干法律问题探究
- 江苏学业水平测试《机械基础》模拟试题
- 选课走班实施方案
- 粘度
- 对照表
- 多种
- 第十届中学生古诗文阅读大赛答案(高中文言文阅读训练34-70篇)
- 食品科学与工程导论论文
- 328例子宫腺肌病临床分析论文
- 卧式容器液位体积计算Excel表
- BD9886FV中文资料
- 潭浩强 《C程序设计(第三版)清华大学出版社
- 埋弧焊机安全操作规程
- 常见异常心电图诊断标准
- 防范恶劣天气安全教育主题班会教案
- 2012年江苏省普通高校“专转本”专业计划表(按报考类别排列)调整
- 森林培育学
- 报福小学发放楼氏教育基金奖 - 欢迎您访问安吉教育网 首页
- “十三五”规划重点-拉曼光谱仪项目建议书(立项报告)
- 2020年国家开放大学《教育学》形考四题库与答案
- 青年教师培训制度
- 中国石油大学(远程教育)2013音乐赏析在线作业100分试题答案
- 人民医院门诊病人对护理工作满意度调查表
- 中央空调管道安装技术交底
- 西安交通大学现代远程教育高电压技术(高起专)试卷及答案
- he医院感染管理行政查房的内容研究qq