4/2, 4/3 proportional directional valves, pilot operated,
without electrical position feedback
Type 4WRZ…XE...
Sizes 10, 16, 25, 32
Component series 7X
Maximum operating pressure 350 bar
Maximum flow 1600 l/min RE 29115-XE-B2/09.13 Replaces: 05.11
H7138
Information on the explosion protection:
– Area of application in accordance with the Explosion
Protection Directive 94/9/EC: II 2G
– Type of protection of the valve solenoid:
Ex e mb IIC T4 Gb according to
EN 60079-7:2007/EN 60079-18:2009
Special features of seawater-resistant valves
– The exterior of the valve housing is galvanically coated.
– The seawater resistance is defined by "J" in the order-
ing code.
ATEX units
For explosive areas
Part II Data sheet
What you need to know about these operating instructions
These operating instructions apply to the explosion-proof version of Rexroth valves and consist of the following three parts:
Part I General information 07010-X-B1
Part II Data sheet 29115-XE-B2
Part III Product-specific instructions 29115-XE-B3
You can find further information on the correct handling of Rexroth hydraulic products in our publication "General product informa-
tion on hydraulic products" 07008.
Operating instructions 29115-XE-B0
Actual product may differ
力士乐 比例换向阀
Table of contents
Contents Page
Features 2
Symbols 2
Ordering code and scope of delivery 3
Function, section 4
Technical data 6
Information on the explosion protection 7
Control electronics 7
Electrical connection 8
Characteristic curves 9
Dimensions 13
Pilot oil supply 17
Features
– Pilot operated 2-stage proportional directional valves for
controlling the flow direction and size
– Spring-centered control spool
– Actuation by means of the pilot control valve (3-way pres-
sure reducing valve)
– Solenoid coil can be rotated by 90°
– For subplate mounting:
Porting pattern according to ISO 4401 - … (information
depending on the size)
Subplates available in FE/ZN version (see pages 13 to 16)
Symbols (simplified)
with electrohydraulic actuation
Type 4WRZ…-7X./…Pilot oil supply Type 4WRZ…A.-7X./…
a
b
X = external
Y = external a
Type 4WRZ…-7X./…ET…
Type 4WRZ…A.-7X./…ET…
a b X = internal
Y = internal b
力士乐 比例换向阀
Ordering code and scope of delivery
Electro-hydraulic actuation = Z Size Size 10 = 10Size 16 = 16Size 25 = 25Size 32 = 32
Symbols T
P a
b
a 0b A B a 0
a 0T
P A B = E E1- = E3 = W6- W8-
= W9- = EA
= W6A
For control spools E1- and W8-:
P → A: q V max
B → T: q V /2P → B: q V /2
A → T: q V max For control spools E3- and W9-:
P → A: q V max
B → T: Blocked P → B: q V /2
A → T: q V max (differential circuit, piston top at port A)Important: In spool position "0", control spools W6-, W8-, W9-, W6A have a connec-tion from A → T and
B → T with approx. 2 % of the relevant nominal cross-section.
M = 1) NBR seals V =
FKM seals Important:
Observe compatibil-ity of seals with hydraulic
fluid used!D3 =
With pressure reducing
valve (preset)Pilot oil supply
and return
no code = Pilot oil supply external,pilot oil return external E = Pilot oil supply internal,pilot oil return external ET = Pilot oil supply internal,pilot oil return internal T =
Pilot oil supply external,pilot oil return internal For details, see page 17.
Surface protection
J =
Seawater-resistant, galvanically coated
XE =
Explosion protection, "increased safety",for details see information on the explosion protection,
page 7
Supply voltage of the control electronics
G24 = 24 V direct voltage
6E = Proportional solenoid
7X =
Component series 70 to 79
(70 to 79: Unchanged installation and connection dimensions)
Rated flow 25 = 25 l/min (size 10) 50 = 50 l/min (size 10) 85 = 85 l/min (size 10) 100 = 100 l/min (size 16)150 = 150 l/min (size 16) 220 = 220 l/min (size 25) 325 = 325 l/min (size 25)
360 = 360 l/min (size 32) 520 =
520 l/min (size 32)
Characteristic curves, see pages 9 to 12
4WRZ
7X 6E G24XE J D3
1) Suitable for mineral oils (HL, HLP) according to DIN 51524
Included in the scope of delivery:
Valve operating instructions with declaration of conformity in Part III
力士乐 比例换向阀
Function, section
Type 3DREP 6..2X/..XE...
Pilot control valve type 3DREP 6…
The pilot control valve is a 3-way pressure reducing valve that
is actuated by a proportional solenoid. It converts an electrical
input signal into a proportional pressure output signal and is
used for all valves type 4WRZ ...
The proportional solenoids are controllable wet-pin DC sole-
noids. The solenoids are actuated by external control electronics.
Set-up:
The valve basically consists of:
– Housing (1) with connection surface
– Control spool (2) with pressure measuring pins (3 and 4)
– Solenoids (5 and 6) with central thread Functional description:The pressure in A or B is set by means of the proportional so-
lenoids. The amount of the pressure depends on the current.
With de-energized solenoids (5, 6), the control spool (2) is
held in the central position by means of the compression
springs (8). Ports A and B are connected with T so that the
hydraulic fluid can flow off to the tank without obstructions.
By actuating a proportional solenoid, e.g. solenoid "b" (5), the pressure measuring pin (4) and the control spool (2) with it are moved to the left. This opens the connection from P to A and B to T via orifice-type cross-sections with progressive flow characteristics. With the surface of the pressure measur-ing pin (3) the pressure that builds up in channel A acts on the control spool and against the solenoid force. The pres-sure measuring pin (3) is supported by the solenoid "a". If the pressure exceeds the value set at solenoid "b", the control spool (2) is pushed back against the solenoid force and con-nects A with T until the set pressure is achieved again. The pressure is proportional to the solenoid current.When the solenoid is switched off, the control spool (2) is re-turned to the central position by the compression springs (8).
Important:
If valves version 3DREP 6 C are used, only one solenoid may
be actuated at a time.Valve with two spool positions
(type 3DREP 6…A…)
The function of this valve version basically corresponds to the
valve with three spool positions. This 2 spool position valve
is, however, only equipped with solenoid "b" (5). Instead of
the 2nd proportional solenoid, there is a plug screw (7).Important:The tank line must not be allowed to run empty. With cor-responding installation conditions, a preload valve (preload pressure approx. 2 bar) must be installed.
力士乐 比例换向阀
T A P Y X
B Function, section
Pilot operated proportional directional valves
Type 4WRZ…-7X/..XE...
Valves of the type 4WRZ... are pilot operated 4-way direc-tional valves that are actuated by means of proportional sole-noids. Their function is to control the flow direction and size.Set-up:
The valve basically consists of:
– Pilot control valve (9) with proportional solenoids (5 and 6)– Main valve (10) with main control spool (11) and centering spring (12)Functional description:– With de-energized solenoids (5 and 6), the main control spool (11) is held in central position by means of a center-ing spring (12).– Actuation of the main control spool (11) by means of the pilot control valve (9) – the main control spool is proportion-ally moved – e.g. actuation of solenoid "b" (6)→ Displacement of the control spool (2) to the right, pilot oil reaches the pressure chamber (13) pilot control valve (9) and displaces the main control spool (11) proportionally to the electrical input signal to the left → Connection of P → A and B → T via orifice-type cross-
sections with progressive flow characteristics
– Pilot oil supply to the pilot control valve internally via port P or externally via port X
– Switching off the solenoid (6)
→ Control spool (2) and main control spool (11) are returned to central position
– Flow depending on spool position from P → A and
B → T or P → B and A → T.
Type 4WRZ…-7X/..XE...
力士乐 比例换向阀
Technical data
general
Installation position Any, preferably horizontal Storage temperature range °C –20 … +50Ambient temperature range °C –20 … +60 Weight, maximum
Size 10kg 10Size 16kg 16Size 25kg 21Size 32
kg 45
Surface protection
Galvanized coating
hydraulic
Size
Size
10
16
25
32
Operating pressure range
Pilot control valve Pilot oil supply external or internal
bar 30 … 31530 … 35030 … 35030 … 350Main valve bar Up to 315Up to 350Up to 350Up to 350Return flow pressure
Port T
(external pilot oil return)bar Up to 315Up to 250Up to 250Up to 150Port T
(internal pilot oil return)bar Up to 30Up to 30Up to 30Up to 30Port Y
bar Up to 30Up to 30Up to 30Up to 30Pilot volume
for switching process 0 → 100 %cm 3 1.7 4.61026.5Pilot flow at port X and Y
with stepped input signal 0 → 100 %l/min 3.5 5.5715.9Flow of the main valve l/min
Up to 170
Up to 460
Up to 870
Up to 1600
Hydraulic fluid
Mineral oil (HL, HLP) according to DIN 51524 Additional hydraulic fluids upon request!
Ignition temperature > 180 °C
Hydraulic fluid temperature range °C –20 ... +80 (NBR seals)°C –15 ... +80 (FKM seals)Viscosity range
mm 2/s
20 ... 380 (preferably 30 ... 46)
Maximum admissible degree of contamination of the hydraulic fluid
Class 17/15/12 1)Cleanliness class according to ISO4406 (c)Pilot control valve Main valve Class 18/16/13 1)
Hysteresis
%
≤ 6
1) The cleanliness classes specified for the components
must be adhered to in hydraulic systems. Effective filtra-tion prevents faults and at the same time increases the life cycle of the components. For the selection of the filters see /filter.
力士乐 比例换向阀
Technical data
1) Surface temperature > 50 °C, provide contact protection 2) Important:
A monitoring circuit is to be provided for the monitoring of the solenoid current. We recommend operating the valves with the assemblies described herein.
Information on the explosion protection
Amplifier module for the control of explosion-proof pro-portional directional valves 4WRA...XE, 3DREP 6...XE and 4WRZ...XE
VT-MSPA2-200-1X/V0/0 according to data sheet 30228-200Module for monitoring and limiting the solenoid currents with proportional valves
VT-MUXA2-2-1X/V0/1A according to data sheet 30290
Control electronics 2)
electric
Voltage type Direct current or pulse-width modulated signal with a pulse voltage ≤ 28 V and a frequency ≥ 160 Hz up to max. 500 Hz Type of signal
Analog Maximum current per solenoid A 1.03Duty cycle %100Coil temperature
°C Up to 125
Area of application in accordance with the Explosion Protection Directive 94/9/EC II 2G Type of protection Valve according to EN 13463-1:2009 / EN 13463-5:2011
c T4 X
Type of protection Valve solenoid according to EN 60079-7:2007 / EN 60079-18:2009Ex e mb IIC T4 Gb 1)Type examination certificate Solenoid KEMA 02ATEX2240 X "IECEx Certificate of Conformity" Solenoid IECEx DEK 12.0068X
Special operating conditions for a safe application
– In case of bank assembly, only one solenoid of all valves may be energized at a time.
– In case of valves with two solenoids, maximally one of the solenoids may be energized at a time.
– Only direct current or a pulse-width modulated signal with a pulse voltage ≤ 28 V and frequency ≥ 160 Hz up to max. 500 Hz may be used.
力士乐 比例换向阀
Electrical connection
3) Recommended pre-fuse
Characteristics medium time-lag according to DIN 41571, 1.25 A
Suppressor diode 47 V, 1.5 kW
+( )
(+)
DC/PWM
The type-examination tested valve solenoid is equipped with a terminal box and a type-tested cable gland.The connection is polarity-independent.
Important:
Corresponding to the rated current, a fuse according to DIN 41571 and EN / IEC 60127 has to be connected ahead of every valve solenoid (max. 3 x I rated ).
The shut-off threshold of the fuse has to match the prospec-tive short-circuit current of the supply source.
The prospective short-circuit current of the supply source may amount to a maximum of 1500 A.
This fuse may only be installed outside the explosive area or must be of an explosion-proof design.
Cable gland Type approval II 2G Ex e IIC Gb Threaded connection
M20 x 1.5Protection class according to EN 60529IP66 1)
Line diameter mm 9 (11)
Sealing
Outer sheath sealing
Connection line Line type
Non-armored cables and lines (outer sheath sealing)Temperature range
°C –30 … > +110
1) If installed properly
Properties of the connection terminals
Position Function
Connectable line cross-section 1Operating voltage connection
Single-wire 0.75 … 2.5 mm 2Finely stranded 0.75 … 1.5 mm 22Connection for protective earthing conductor Single-wire max. 2.5 mm 2Finely stranded max. 1.5 mm 23
Connection for potential equalization conductor
Single-wire 4 … 6 mm 2Finely stranded 4 mm 2
力士乐 比例换向阀
Characteristic curves size 10
(measured with control spools E, W6-, EA, W6A as well as HLP46, ?oil = 40 °C ± 5 °C)
100020050
15025051
4321000255075
1000
900
800700
600
500
470
150********
020
408060
1
23410075250
50020
406080100020
40
6080100
1?p = 10 bar constant
2?p = 20 bar constant 3?p = 30 bar constant 4?p = 50 bar constant 5?p = 100 bar constant
1?p = 10 bar constant
2?p = 20 bar constant 3?p = 30 bar constant 4?p = 50 bar constant 5?p = 100 bar constant
1?p = 10 bar constant 2?p = 20 bar constant
3?p = 30 bar constant 4?p = 50 bar constant 5?p = 100 bar constant
Ordering code 25: Flow Ordering code 85: Flow Ordering code 50: Flow ?p = valve pressure differential according to DIN 24311 (inlet pressure p P minus load pressure p L minus return flow pressure p T )Transition function with stepped electric input signals
Current in mA →
Current in mA →
Current in mA →
F l o w i n l /m i n →
F l o w i n l /m i n →
F l o w i n l /m i n →
S t r o k e i n % →
Time in ms →
Time in ms →
Change of input signal [%]1
0 → 25 → 0
20 → 50 → 030 → 75 → 04
0 → 100 → 0
Measured at pilot pressure p ST = 50 bar
力士乐 比例换向阀
Characteristic curves size 16
(measured with control spools E, W6-, EA, W6A as well as HLP46, ?oil = 40 °C ± 5 °C)
?p = valve pressure differential according to DIN 24311 (inlet pressure p P minus load pressure p L minus return flow pressure p T )
Transition function with stepped electric input signals
5025751001208040
1602000
12080401602000
1
23
41600408012024020032028054321
1?p = 10 bar constant 2?p = 20 bar constant 3?p = 30 bar constant 4?p = 50 bar constant 5?p = 100 bar constant
Ordering code 100: Flow Current in mA →
F l o w i n l /m i n →
S t r o k e i n % →
Time in ms →
Time in ms →
24008016044040032054321
1?p = 10 bar constant 2?p = 20 bar constant 3?p = 30 bar constant 4?p = 50 bar constant 5?p = 100 bar constant
Ordering code 150: Flow Current in mA →
F l o w i n l /m i n →
Change of input signal [%]10 → 25 → 020 → 50 → 030 → 75 → 04
0 → 100 → 0
Measured at pilot pressure p ST = 50 bar
力士乐 比例换向阀
Characteristic curves size 25
(measured with control spools E, W6-, EA, W6A as well as HLP46, ?oil = 40 °C ± 5 °C)
4000100200300500
54321
8000100200300400500600700
800700600
500
470
54321
50257510015010050
20025001
234150100
50
200
250
0?p = valve pressure differential according to DIN 24311 (inlet pressure p P minus load pressure p L minus return flow pressure p T )
Transition function with stepped electric input signals
1?p = 10 bar constant 2?p = 20 bar constant 3?p = 30 bar constant 4?p = 50 bar constant 5?p = 100 bar constant
Ordering code 220: Flow Current in mA →
F l o w i n l /m i n →
S t r o k e i n % →
Time in ms →
Time in ms →1?p = 10 bar constant 2?p = 20 bar constant 3?p = 30 bar constant 4?p = 50 bar constant 5?p = 100 bar constant
Ordering code 325: Flow Current in mA →
F l o w i n l /m i n →
Change of input signal [%]
10 → 25 → 020 → 50 → 030 → 75 → 04
0 → 100 → 0
Measured at pilot pressure p ST = 50 bar
力士乐 比例换向阀
Characteristic curves size 32
(measured with control spools E, W6-, EA, W6A as well as HLP46, ?oil = 40 °C ± 5 °C)
80002004006001000
900800700600
500
470
5
432
1
130012001000160002004006008001000120014001000
900
800700600
500
470
5
43
21
18001
23410075250
500
80
160240320400
80160240320400?p = valve pressure differential according to DIN 24311 (inlet pressure p P minus load pressure p L minus return flow pressure p T )
Change of input signal [%]10 → 25 → 020 → 50 → 030 → 75 → 04
0 → 100 → 0
Transition function with stepped electric input signals
1?p = 10 bar constant 2?p = 20 bar constant 3?p = 30 bar constant 4?p = 50 bar constant 5?p = 100 bar constant
Ordering code 360: Flow Current in mA →
F l o w i n l /m i n →
S t r o k e i n % →
Time in ms →
Time in ms →
1?p = 10 bar constant 2?p = 20 bar constant 3?p = 30 bar constant 4?p = 50 bar constant
5?p = 100 bar constant
Ordering code 520: Flow Current in mA →
F l o w i n l /m i n →
Measured at pilot pressure p ST = 50 bar
力士乐 比例换向阀
Dimensions size 10 (dimensions in mm)
1Main valve
2Pilot control valve
3Proportional solenoid "a"
4Proportional solenoid "b"
5Terminal box
6Plug screw for valves with one solenoid
7Name plate for pilot control valve
8Name plate for main valve
9Pressure reducing valve (always available)
10Identical seal rings for ports P, A, B, T and T1
11Identical seal rings for X and Y
12Machined valve contact surface, porting pattern ac-cording to ISO 4401-05-05-0-05 (X, Y as required, T1 is available at the valve and can optionally be provided)
Deviating from the standard:
- Locating pin not available Subplates
G 534/01 FE/ZN (G3/4) without ports X and Y
G 535/01 FE/ZN (G3/4) with ports X and Y
G 536/01 FE/ZN (G1) with ports X and Y
with dimensions as in the data sheet 45054 must be or-dered separately.
Valve mounting screws
For reasons of stability, exclusively use the following valve mounting screws:
4 hexagon socket head cap screws
ISO 4762-M6x45-10.9-flZn-240h-L
(friction coefficient total: 0.09-0.14 according to VDA 235-101) (must be ordered separately)
Important:
Subplates are no components in the sense of directive 94/9/EC and can be used after the manufacturer of the overall system has assessed the risk of ignition.
The G...FE/ZN versions are free from aluminum and/or mag-nesium and galvanized.
力士乐 比例换向阀
Dimensions size 16 (dimensions in mm)
1Main valve
2Pilot control valve
3Proportional solenoid "a"4Proportional solenoid "b"5Terminal box
6Plug screw for valves with one solenoid 7Name plate for pilot control valve 8Name plate for main valve
9Pressure reducing valve (always available)10Identical seal rings for ports P, A, B and T 11Identical seal rings for X and Y
12
Machined valve contact surface valve contact face, porting pattern according to ISO 4401-07-07-0-05 (X, Y as required)
Deviating from the standard:
– Ports P, A, B and T with Ø 20 mm 13Locating pin 12
Required surface quality of the
valve contact surface
Subplates
G 172/01 FE/ZN (G3/4) G 172/02 FE/ZN (M27 x 2)G 174/01 FE/ZN (G1)
G 174/02 FE/ZN (M33 x 2) G 174/08 FE/ZN (flange)with dimensions as in the data sheet 45056 must be or-dered separately.
Valve mounting screws
For reasons of stability, exclusively use the following valve mounting screws:
2 hexagon socket head cap screws ISO 4762-M6x60-10.9-flZn-240h-L
(friction coefficient total: 0.09-0.14 according to VDA 235-101)(must be ordered separately)
4 hexagon socket head cap screws ISO 4762-M10x60-10.9-flZn-240h-L
(total friction coefficient: 0.09-0.14 according to VDA 235-101)(must be ordered separately)Important:
Subplates are no components in the sense of directive 94/9/EC and can be used after the manufacturer of the overall system has assessed the risk of ignition.
The G...FE/ZN versions are free from aluminum and/or mag-nesium and galvanized.
力士乐 比例换向阀
Dimensions size 25 (dimensions in mm)
1Main valve
2Pilot control valve
3Proportional solenoid "a"4Proportional solenoid "b"5Terminal box
6Plug screw for valves with one solenoid 7Name plate for pilot control valve 8Name plate for main valve
9Pressure reducing valve (always available)10Identical seal rings for ports P, A, B and T 11Identical seal rings for X and Y
12
Machined valve contact surface, porting pattern accord-ing to ISO 4401-08-08-0-05 (X, Y as required)13Locating pin
12
Required surface quality of the
valve contact surface
Subplates
G 151/01 FE/ZN (G1)
G 154/01 FE/ZN (G1 1/4) G 154/08 FE/ZN (flange)G 156/01 FE/ZN (G1 1/2)
with dimensions as in the data sheet 45058 must be or-dered separately.Valve mounting screws
For reasons of stability, exclusively use the following valve mounting screws:
6 hexagon socket head cap screws ISO 4762-M12x60-10.9-flZn-240h-L
(friction coefficient total: 0.09-0.14 according to VDA 235-101)(must be ordered separately)Important:
Subplates are no components in the sense of directive 94/9/EC and can be used after the manufacturer of the overall system has assessed the risk of ignition.
The G...FE/ZN versions are free from aluminum and/or mag-nesium and galvanized.
力士乐 比例换向阀
11
10
Dimensions size 32 (dimensions in mm)
1Main valve
2Pilot control valve
3Proportional solenoid "a"4Proportional solenoid "b"5Terminal box
6Plug screw for valves with one solenoid 7Name plate for pilot control valve 8Name plate for main valve
9Pressure reducing valve (always available)10Identical seal rings for ports P, A, B and T 11Identical seal rings for X and Y
12
Machined valve contact surface, porting pattern accord-ing to ISO 4401-10-09-0-05 (X, Y as required)
Deviating from the standard:
– Ports P, A, B and T with Ø 38 mm 13Locating pin
12Required surface quality of the
valve contact surface
Subplates
G 157/01 FE/ZN (G1 1/2)G 157/02 FE/ZN (M48 x 2)G 158/10 FE/ZN (flange)
with dimensions as in the data sheet 45060 must be or-dered separately.Valve mounting screws
For reasons of stability, exclusively use the following valve mounting screws:
6 hexagon socket head cap screws ISO 4762-M20x80-10.9-flZn-240h-L
(friction coefficient total: 0.09-0.14 according to VDA 235-101)(must be ordered separately)Important:
Subplates are no components in the sense of directive 94/9/EC and can be used after the manufacturer of the overall system has assessed the risk of ignition.
The G...FE/ZN versions are free from aluminum and/or mag-nesium and galvanized.
力士乐 比例换向阀
Type 4WRZ…-…/…
Pilot oil supply external
Pilot oil return external
In this version, the pilot oil is supplied from a separate pilot circuit (external).
The pilot oil return is not directed into the T channel of
the main valve, but is separately directed to the tank via
port Y (external).
Type 4WRZ…-…/…E…
Pilot oil supply internal
Pilot oil return external
In this version, the pilot oil is supplied via the P channel of the main valve (internal).
The pilot oil return is not directed into the T channel of
the main valve, but is separately directed to the tank via
port Y (external).
In the subplate, port X is to be closed.Type 4WRZ…-…/…ET…
Pilot oil supply internal
Pilot oil return internal
In this version, the pilot oil is supplied via the P channel of the main valve (internal).
The pilot oil is directly returned to channel T of the main valve (internal).
In the subplate, ports X and Y are to be closed.
Type 4WRZ…-…/…T…
Pilot oil supply external
Pilot oil return internal
In this version, the pilot oil is supplied from a separate pilot circuit (external).
The pilot oil is directly returned to channel T of the main valve (internal).
In the subplate, port Y is to be closed.
Pilot oil supply
力士乐 比例换向阀
Bosch Rexroth AG Hydraulics
Zum Eisengießer 1
97816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 documentation@boschrexroth.de www.boschrexroth.de © This document, as well as the data, specifications and other informa-tion set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No state-ments concerning a certain condition or suitability for a certain applica-tion can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.
Notes
力士乐 比例换向阀
Bosch Rexroth AG Hydraulics
Zum Eisengießer 1
97816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 documentation@boschrexroth.de www.boschrexroth.de © This document, as well as the data, specifications and other informa-tion set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No state-ments concerning a certain condition or suitability for a certain applica-tion can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.
Notes
力士乐 比例换向阀
Bosch Rexroth AG Hydraulics
Zum Eisengießer 1
97816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 documentation@boschrexroth.de www.boschrexroth.de © This document, as well as the data, specifications and other informa-tion set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No state-ments concerning a certain condition or suitability for a certain applica-tion can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.
Notes
正在阅读:
力士乐比例换向阀05-24
河南财经学院2009至2010学年第1学期商法学期末考试试题A05-05
学优练七年级历史下册 第15课 明朝君权的加强学案 新05-08
关于总行成立营销团队有关说想07-19
电影观后感格式04-01
研究生英语系列教程多维教程熟谙正文翻译05-29
儿童之家的教育宗旨11-02
理论塔板数04-26
2020年小升初面试的7个技巧05-01
- 教学能力大赛决赛获奖-教学实施报告-(完整图文版)
- 互联网+数据中心行业分析报告
- 2017上海杨浦区高三一模数学试题及答案
- 招商部差旅接待管理制度(4-25)
- 学生游玩安全注意事项
- 学生信息管理系统(文档模板供参考)
- 叉车门架有限元分析及系统设计
- 2014帮助残疾人志愿者服务情况记录
- 叶绿体中色素的提取和分离实验
- 中国食物成分表2020年最新权威完整改进版
- 推动国土资源领域生态文明建设
- 给水管道冲洗和消毒记录
- 计算机软件专业自我评价
- 高中数学必修1-5知识点归纳
- 2018-2022年中国第五代移动通信技术(5G)产业深度分析及发展前景研究报告发展趋势(目录)
- 生产车间巡查制度
- 2018版中国光热发电行业深度研究报告目录
- (通用)2019年中考数学总复习 第一章 第四节 数的开方与二次根式课件
- 2017_2018学年高中语文第二单元第4课说数课件粤教版
- 上市新药Lumateperone(卢美哌隆)合成检索总结报告
- 换向阀
- 力士
- 比例
- 城关一小2011年电化教育发展规划
- 阀门渗漏的原因分析及预防措施
- 基于DELPHI实现PC机与MCS-51单片机的串行通信
- 如何建立终端店铺培训体系与模板
- 外文文献(零传动滚齿机滚刀架进给部件设计)
- 2008汶川地震强震记录相关分析及与国内外地震记录对比
- 防雷接地技术交底
- 鲁教版七年级下册13课第一框_你了解自己的情绪吗?
- 日本城市色彩营造研究_王占柱
- 基于AT89S52单片机智能搬运机器人的设计
- 合肥市关于开展加载金融功能社会保障卡
- 曝气生物滤池设计
- 海南椰都联合资信评估有限公司企业资信等级评估公告
- 学校下期德育工作总结
- 现代服务业“营改增”实务培训
- 电化学腐蚀法制备针尖的试验研究
- 【八十年代至今重大刑事案】马汉庆系列持枪杀人抢劫案
- 世界各国的公共假日
- 重庆谈判与双十协定1
- 《党章》《准则》《条例》学习心得